{"product_id":"uni-3-2-2-w3-dual-arm-self-cleaning-mobile-filter-unit-for-welding-fumes-with-10-flex-arms","title":"UNI 3.2.2 W3: Dual-Arm Self-Cleaning Mobile Filter Unit for Welding Fumes with 10' Flex Arms","description":"\u003ch2 data-section-id=\"1rgun55\" data-start=\"96\" data-end=\"174\"\u003eSelf-Cleaning Dual-Station Welding Fume Extraction with Maximum Flexibility\u003c\/h2\u003e\n\u003cp data-start=\"176\" data-end=\"676\"\u003eThe \u003cstrong data-start=\"180\" data-end=\"226\"\u003eAerService UNI 3.2.2 W3 with 10' Flex Arms\u003c\/strong\u003e is a self-cleaning mobile welding fume extraction system engineered for fabrication facilities requiring simultaneous source-capture extraction at two welding stations. Combining W3-certified filtration, automatic compressed-air filter cleaning, and dual 10' Flex Arms, this configuration delivers powerful extraction performance while providing exceptional positioning flexibility for multiple operators working in dynamic fabrication environments.\u003c\/p\u003e\n\u003cp data-start=\"678\" data-end=\"1109\"\u003eDesigned for intensive daily welding operations, the UNI 3.2.2 W3 allows two operators to capture welding fumes directly at the source while sharing a single high-capacity filtration system. The included 10' Flex Arms (3m) provide outstanding maneuverability and adaptability, making this configuration ideal for fabrication facilities where workpieces, weld locations, and workstation layouts frequently change throughout the day.\u003c\/p\u003e\n\u003chr data-start=\"1111\" data-end=\"1114\"\u003e\n\u003ch2 data-section-id=\"q8vpv9\" data-start=\"1116\" data-end=\"1140\"\u003eWhy a Dual-Arm Setup?\u003c\/h2\u003e\n\u003cp data-start=\"1142\" data-end=\"1398\"\u003eMany fabrication facilities operate multiple welding stations within the same work area. Installing a dedicated extraction unit at every workstation can increase equipment costs, consume valuable floor space, and create additional maintenance requirements.\u003c\/p\u003e\n\u003cp data-start=\"1400\" data-end=\"1594\"\u003eThe UNI 3.2.2 W3 addresses these challenges by allowing two operators to share a single high-capacity filtration system while maintaining effective source-capture extraction at each workstation.\u003c\/p\u003e\n\u003cp data-start=\"1596\" data-end=\"1633\"\u003eBenefits of a dual-arm setup include:\u003c\/p\u003e\n\u003cul data-start=\"1635\" data-end=\"2009\"\u003e\n\u003cli data-section-id=\"1t7y4zi\" data-start=\"1635\" data-end=\"1686\"\u003eSimultaneous extraction for two welding stations.\u003c\/li\u003e\n\u003cli data-section-id=\"23f8c1\" data-start=\"1687\" data-end=\"1756\"\u003eReduced equipment investment compared to multiple extraction units.\u003c\/li\u003e\n\u003cli data-section-id=\"12hkxx0\" data-start=\"1757\" data-end=\"1790\"\u003eLower maintenance requirements.\u003c\/li\u003e\n\u003cli data-section-id=\"buqu8s\" data-start=\"1791\" data-end=\"1827\"\u003eMore efficient use of floor space.\u003c\/li\u003e\n\u003cli data-section-id=\"vrqkcz\" data-start=\"1828\" data-end=\"1884\"\u003eIncreased productivity in multi-operator environments.\u003c\/li\u003e\n\u003cli data-section-id=\"3s6mvm\" data-start=\"1885\" data-end=\"1943\"\u003eFlexible extraction coverage across multiple work areas.\u003c\/li\u003e\n\u003cli data-section-id=\"1ctpgx6\" data-start=\"1944\" data-end=\"2009\"\u003eCentralized filtration with simplified service and maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2011\" data-end=\"2255\"\u003eFor fabrication shops, manufacturing facilities, and welding cells where multiple operators work in close proximity, a dual-arm extraction system provides an efficient solution for maintaining air quality while maximizing equipment utilization.\u003c\/p\u003e\n\u003chr data-start=\"2257\" data-end=\"2260\"\u003e\n\u003ch2 data-section-id=\"fwuni5\" data-start=\"2262\" data-end=\"2290\"\u003eWhy Choose 10' Flex Arms?\u003c\/h2\u003e\n\u003cp data-start=\"2292\" data-end=\"2409\"\u003eThe 10' Flex Arm configuration is designed for facilities where versatility and positioning flexibility are critical.\u003c\/p\u003e\n\u003cp data-start=\"2411\" data-end=\"2428\"\u003eBenefits include:\u003c\/p\u003e\n\u003cul data-start=\"2430\" data-end=\"2721\"\u003e\n\u003cli data-section-id=\"4u8rcx\" data-start=\"2430\" data-end=\"2460\"\u003eMaximum arm maneuverability.\u003c\/li\u003e\n\u003cli data-section-id=\"j62njd\" data-start=\"2461\" data-end=\"2505\"\u003eEasy positioning around complex weldments.\u003c\/li\u003e\n\u003cli data-section-id=\"1n28wfw\" data-start=\"2506\" data-end=\"2545\"\u003eQuick adjustments during fabrication.\u003c\/li\u003e\n\u003cli data-section-id=\"1ryj7x1\" data-start=\"2546\" data-end=\"2591\"\u003eExcellent reach across multiple work areas.\u003c\/li\u003e\n\u003cli data-section-id=\"15xzojj\" data-start=\"2592\" data-end=\"2647\"\u003eImproved access to difficult-to-reach weld locations.\u003c\/li\u003e\n\u003cli data-section-id=\"1nk3unr\" data-start=\"2648\" data-end=\"2721\"\u003eIdeal for changing workstation layouts and custom fabrication projects.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2723\" data-end=\"2874\"\u003eThis configuration is particularly beneficial for fabrication environments where workpieces and welding positions frequently change throughout the day.\u003c\/p\u003e\n\u003chr data-start=\"2876\" data-end=\"2879\"\u003e\n\u003ch2 data-section-id=\"anecoi\" data-start=\"2881\" data-end=\"2930\"\u003eDesigned for Intensive Industrial Applications\u003c\/h2\u003e\n\u003cp data-start=\"2932\" data-end=\"3085\"\u003eThe UNI 3.2.2 W3 is built for fabrication environments where welding, grinding, and thermal cutting activities occur continuously throughout the workday.\u003c\/p\u003e\n\u003cp data-start=\"3087\" data-end=\"3114\"\u003eIdeal applications include:\u003c\/p\u003e\n\u003cul data-start=\"3116\" data-end=\"3357\"\u003e\n\u003cli data-section-id=\"1nk1y2u\" data-start=\"3116\" data-end=\"3147\"\u003eHeavy fabrication facilities.\u003c\/li\u003e\n\u003cli data-section-id=\"1vmyto2\" data-start=\"3148\" data-end=\"3171\"\u003eManufacturing plants.\u003c\/li\u003e\n\u003cli data-section-id=\"oq8yl5\" data-start=\"3172\" data-end=\"3204\"\u003eProduction welding operations.\u003c\/li\u003e\n\u003cli data-section-id=\"1bdk7kn\" data-start=\"3205\" data-end=\"3235\"\u003eMulti-station welding cells.\u003c\/li\u003e\n\u003cli data-section-id=\"dc9udn\" data-start=\"3236\" data-end=\"3273\"\u003eIndustrial maintenance departments.\u003c\/li\u003e\n\u003cli data-section-id=\"wek2ao\" data-start=\"3274\" data-end=\"3300\"\u003eMetal fabrication shops.\u003c\/li\u003e\n\u003cli data-section-id=\"1fioyoi\" data-start=\"3301\" data-end=\"3357\"\u003eFacilities generating welding fumes and grinding dust.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3359\" data-end=\"3496\"\u003eIts dual-arm configuration makes it particularly effective in environments where multiple operators require simultaneous fume extraction.\u003c\/p\u003e\n\u003chr data-start=\"3498\" data-end=\"3501\"\u003e\n\u003ch2 data-section-id=\"bafxwr\" data-start=\"3503\" data-end=\"3541\"\u003eW3-Certified Filtration Performance\u003c\/h2\u003e\n\u003cp data-start=\"3543\" data-end=\"3729\"\u003eThe UNI 3.2.2 W3 is certified to \u003cstrong data-start=\"3576\" data-end=\"3603\"\u003eW3 filtration standards\u003c\/strong\u003e with filtration efficiency exceeding \u003cstrong data-start=\"3641\" data-end=\"3648\"\u003e99%\u003c\/strong\u003e, providing high-performance welding fume filtration for industrial applications.\u003c\/p\u003e\n\u003cp data-start=\"3731\" data-end=\"3762\"\u003eThe filtration system includes:\u003c\/p\u003e\n\u003ch3 data-section-id=\"10qh9cm\" data-start=\"3764\" data-end=\"3790\"\u003ePre-Separation Chamber\u003c\/h3\u003e\n\u003cp data-start=\"3792\" data-end=\"3973\"\u003eA dedicated pre-separation chamber captures heavier dust and sparks before they reach the primary filtration cartridges, helping extend filter life and maintain airflow performance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"jw147v\" data-start=\"3975\" data-end=\"4004\"\u003eDual Cartridge Filtration\u003c\/h3\u003e\n\u003cp data-start=\"4006\" data-end=\"4179\"\u003eTwo high-capacity cartridge filters utilizing \u003cstrong data-start=\"4052\" data-end=\"4084\"\u003eSintexx Plus nanofiber media\u003c\/strong\u003e provide exceptional particulate capture efficiency while supporting continuous-duty operation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"de96ni\" data-start=\"4181\" data-end=\"4218\"\u003eAutomatic Compressed-Air Cleaning\u003c\/h3\u003e\n\u003cp data-start=\"4220\" data-end=\"4410\"\u003eThe integrated reverse-pulse cleaning system automatically removes accumulated particulate from the filter surface, reducing maintenance requirements and helping maintain consistent airflow.\u003c\/p\u003e\n\u003chr data-start=\"4412\" data-end=\"4415\"\u003e\n\u003ch2 data-section-id=\"1sq4lf\" data-start=\"4417\" data-end=\"4451\"\u003eAdvanced Digital Control System\u003c\/h2\u003e\n\u003cp data-start=\"4453\" data-end=\"4565\"\u003eThe UNI 3.2.2 W3 features a digital control panel designed to simplify operation and monitor system performance.\u003c\/p\u003e\n\u003cp data-start=\"4567\" data-end=\"4584\"\u003eFeatures include:\u003c\/p\u003e\n\u003cul data-start=\"4586\" data-end=\"4760\"\u003e\n\u003cli data-section-id=\"1n0491x\" data-start=\"4586\" data-end=\"4613\"\u003eMulti-language interface.\u003c\/li\u003e\n\u003cli data-section-id=\"1q8rizx\" data-start=\"4614\" data-end=\"4627\"\u003eHour meter.\u003c\/li\u003e\n\u003cli data-section-id=\"1erkvn7\" data-start=\"4628\" data-end=\"4648\"\u003eAlarm history log.\u003c\/li\u003e\n\u003cli data-section-id=\"u2ddfu\" data-start=\"4649\" data-end=\"4669\"\u003eFilter monitoring.\u003c\/li\u003e\n\u003cli data-section-id=\"e5yl6c\" data-start=\"4670\" data-end=\"4693\"\u003eClogged filter alarm.\u003c\/li\u003e\n\u003cli data-section-id=\"ymte4a\" data-start=\"4694\" data-end=\"4722\"\u003eCompressed-air monitoring.\u003c\/li\u003e\n\u003cli data-section-id=\"1g9zqyv\" data-start=\"4723\" data-end=\"4760\"\u003eAutomatic Start\/Stop functionality.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4762\" data-end=\"4869\"\u003eThese capabilities help operators maintain peak extraction performance while minimizing unplanned downtime.\u003c\/p\u003e\n\u003chr data-start=\"4871\" data-end=\"4874\"\u003e\n\u003ch2 data-section-id=\"p78do1\" data-start=\"4876\" data-end=\"4919\"\u003eOptimized Airflow for Dual-Arm Operation\u003c\/h2\u003e\n\u003cp data-start=\"4921\" data-end=\"5051\"\u003eThe UNI 3.2.2 W3 is specifically configured to support two extraction arms while maintaining effective source-capture performance.\u003c\/p\u003e\n\u003cp data-start=\"5053\" data-end=\"5070\"\u003eFeatures include:\u003c\/p\u003e\n\u003cul data-start=\"5072\" data-end=\"5240\"\u003e\n\u003cli data-section-id=\"k8poj3\" data-start=\"5072\" data-end=\"5105\"\u003ePlug-fan extraction technology.\u003c\/li\u003e\n\u003cli data-section-id=\"1ghqtvv\" data-start=\"5106\" data-end=\"5137\"\u003eHigh-capacity airflow design.\u003c\/li\u003e\n\u003cli data-section-id=\"1y2ocdl\" data-start=\"5138\" data-end=\"5168\"\u003eAirflow equalization system.\u003c\/li\u003e\n\u003cli data-section-id=\"hyq78z\" data-start=\"5169\" data-end=\"5198\"\u003eDual-stage dust collection.\u003c\/li\u003e\n\u003cli data-section-id=\"8hhpxg\" data-start=\"5199\" data-end=\"5240\"\u003eOptimized discharge airflow management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5242\" data-end=\"5416\"\u003eThe system provides up to \u003cstrong data-start=\"5268\" data-end=\"5313\"\u003e1,177 CFM (2,000m³\/h) extraction capacity\u003c\/strong\u003e, delivering approximately \u003cstrong data-start=\"5340\" data-end=\"5363\"\u003e588 CFM (1,000m³\/h)\u003c\/strong\u003e per arm when both arms are operating simultaneously.\u003c\/p\u003e\n\u003chr data-start=\"5418\" data-end=\"5421\"\u003e\n\u003ch2 data-section-id=\"x43ryu\" data-start=\"5423\" data-end=\"5445\"\u003eSupported Processes\u003c\/h2\u003e\n\u003cp data-start=\"5447\" data-end=\"5480\"\u003eThe UNI 3.2.2 W3 is suitable for:\u003c\/p\u003e\n\u003cul data-start=\"5482\" data-end=\"5616\"\u003e\n\u003cli data-section-id=\"1l448pd\" data-start=\"5482\" data-end=\"5495\"\u003eMIG Welding\u003c\/li\u003e\n\u003cli data-section-id=\"1cggtnd\" data-start=\"5496\" data-end=\"5509\"\u003eMAG Welding\u003c\/li\u003e\n\u003cli data-section-id=\"116658u\" data-start=\"5510\" data-end=\"5534\"\u003ePulsed MIG\/MAG Welding\u003c\/li\u003e\n\u003cli data-section-id=\"qyiua0\" data-start=\"5535\" data-end=\"5548\"\u003eTIG Welding\u003c\/li\u003e\n\u003cli data-section-id=\"v9v5qy\" data-start=\"5549\" data-end=\"5570\"\u003eMMA \/ Stick Welding\u003c\/li\u003e\n\u003cli data-section-id=\"3717ra\" data-start=\"5571\" data-end=\"5594\"\u003eManual Plasma Cutting\u003c\/li\u003e\n\u003cli data-section-id=\"12uhkrc\" data-start=\"5595\" data-end=\"5616\"\u003eGrinding Operations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5618\" data-end=\"5699\"\u003eThe unit is designed for dry welding fumes and dust generated by these processes.\u003c\/p\u003e\n\u003chr data-start=\"5701\" data-end=\"5704\"\u003e\n\u003ch2 data-section-id=\"19vd27d\" data-start=\"5706\" data-end=\"5727\"\u003eIdeal Applications\u003c\/h2\u003e\n\u003cp data-start=\"5729\" data-end=\"5794\"\u003eThe UNI 3.2.2 W3 with 10' Flex Arms is an excellent solution for:\u003c\/p\u003e\n\u003cul data-start=\"5796\" data-end=\"6058\"\u003e\n\u003cli data-section-id=\"1pa6bpk\" data-start=\"5796\" data-end=\"5824\"\u003eDual welding workstations.\u003c\/li\u003e\n\u003cli data-section-id=\"9odpnm\" data-start=\"5825\" data-end=\"5852\"\u003eCustom fabrication shops.\u003c\/li\u003e\n\u003cli data-section-id=\"6zw4md\" data-start=\"5853\" data-end=\"5880\"\u003eManufacturing facilities.\u003c\/li\u003e\n\u003cli data-section-id=\"cgnqbh\" data-start=\"5881\" data-end=\"5901\"\u003eRepair operations.\u003c\/li\u003e\n\u003cli data-section-id=\"de3pcm\" data-start=\"5902\" data-end=\"5936\"\u003eMaintenance welding departments.\u003c\/li\u003e\n\u003cli data-section-id=\"ibj63k\" data-start=\"5937\" data-end=\"5961\"\u003eTraining environments.\u003c\/li\u003e\n\u003cli data-section-id=\"ucltjr\" data-start=\"5962\" data-end=\"5997\"\u003eMulti-operator fabrication cells.\u003c\/li\u003e\n\u003cli data-section-id=\"4w60sp\" data-start=\"5998\" data-end=\"6058\"\u003eApplications requiring maximum extraction arm flexibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6060\" data-end=\"6063\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"6065\" data-end=\"6080\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"6082\" data-end=\"6580\"\u003e\n\u003cli data-section-id=\"187bup2\" data-start=\"6082\" data-end=\"6116\"\u003eIncludes two 10' Flex Arms (3m).\u003c\/li\u003e\n\u003cli data-section-id=\"1jopxsz\" data-start=\"6117\" data-end=\"6171\"\u003eW3-certified filtration efficiency greater than 99%.\u003c\/li\u003e\n\u003cli data-section-id=\"wq2c4c\" data-start=\"6172\" data-end=\"6205\"\u003eDual-arm extraction capability.\u003c\/li\u003e\n\u003cli data-section-id=\"o37626\" data-start=\"6206\" data-end=\"6249\"\u003eAutomatic compressed-air filter cleaning.\u003c\/li\u003e\n\u003cli data-section-id=\"iz4sdv\" data-start=\"6250\" data-end=\"6285\"\u003eDual-cartridge filtration system.\u003c\/li\u003e\n\u003cli data-section-id=\"1d29ih\" data-start=\"6286\" data-end=\"6324\"\u003eSintexx Plus nanofiber filter media.\u003c\/li\u003e\n\u003cli data-section-id=\"p2jd1h\" data-start=\"6325\" data-end=\"6377\"\u003ePre-separation chamber for spark and dust removal.\u003c\/li\u003e\n\u003cli data-section-id=\"k8poj3\" data-start=\"6378\" data-end=\"6411\"\u003ePlug-fan extraction technology.\u003c\/li\u003e\n\u003cli data-section-id=\"q62kt\" data-start=\"6412\" data-end=\"6436\"\u003eDigital control panel.\u003c\/li\u003e\n\u003cli data-section-id=\"1g9zqyv\" data-start=\"6437\" data-end=\"6474\"\u003eAutomatic Start\/Stop functionality.\u003c\/li\u003e\n\u003cli data-section-id=\"ymte4a\" data-start=\"6475\" data-end=\"6503\"\u003eCompressed-air monitoring.\u003c\/li\u003e\n\u003cli data-section-id=\"1erkvn7\" data-start=\"6504\" data-end=\"6524\"\u003eAlarm history log.\u003c\/li\u003e\n\u003cli data-section-id=\"e5yl6c\" data-start=\"6525\" data-end=\"6548\"\u003eClogged filter alarm.\u003c\/li\u003e\n\u003cli data-section-id=\"1eszi9q\" data-start=\"6549\" data-end=\"6580\"\u003eDual dust collection drawers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6582\" data-end=\"6585\"\u003e\n\u003ch2 data-section-id=\"1kmusxh\" data-start=\"6587\" data-end=\"6603\"\u003eConfiguration\u003c\/h2\u003e\n\u003cp data-start=\"6605\" data-end=\"6646\"\u003e\u003cstrong data-start=\"6605\" data-end=\"6623\"\u003eIncluded Arms:\u003c\/strong\u003e Two 10' Flex Arms (3m)\u003c\/p\u003e\n\u003chr data-start=\"6648\" data-end=\"6651\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"6653\" data-end=\"6680\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"6682\" data-end=\"6721\"\u003e\u003cstrong data-start=\"6682\" data-end=\"6699\"\u003eFan Capacity:\u003c\/strong\u003e 1,483 CFM (2,520m³\/h)\u003c\/p\u003e\n\u003cp data-start=\"6723\" data-end=\"6769\"\u003e\u003cstrong data-start=\"6723\" data-end=\"6747\"\u003eExtraction Capacity:\u003c\/strong\u003e 1,177 CFM (2,000m³\/h)\u003c\/p\u003e\n\u003cp data-start=\"6771\" data-end=\"6823\"\u003e\u003cstrong data-start=\"6771\" data-end=\"6803\"\u003eExtraction Capacity Per Arm:\u003c\/strong\u003e 588 CFM (1,000m³\/h)\u003c\/p\u003e\n\u003cp data-start=\"6825\" data-end=\"6869\"\u003e\u003cstrong data-start=\"6825\" data-end=\"6851\"\u003eFiltration Efficiency:\u003c\/strong\u003e W3 Certified \u0026gt;99%\u003c\/p\u003e\n\u003cp data-start=\"6871\" data-end=\"6904\"\u003e\u003cstrong data-start=\"6871\" data-end=\"6887\"\u003eFilter Area:\u003c\/strong\u003e 172 sq ft (16m²)\u003c\/p\u003e\n\u003cp data-start=\"6906\" data-end=\"6946\"\u003e\u003cstrong data-start=\"6906\" data-end=\"6923\"\u003eFilter Media:\u003c\/strong\u003e Sintexx Plus Nanofiber\u003c\/p\u003e\n\u003cp data-start=\"6948\" data-end=\"6977\"\u003e\u003cstrong data-start=\"6948\" data-end=\"6964\"\u003eMotor Power:\u003c\/strong\u003e 2 HP (1.5kW)\u003c\/p\u003e\n\u003cp data-start=\"6979\" data-end=\"7042\"\u003e\u003cstrong data-start=\"6979\" data-end=\"6991\"\u003eVoltage:\u003c\/strong\u003e 230V \/ 1 Phase \/ 50Hz or 400V \/ 3 Phase \/ 50-60Hz*\u003c\/p\u003e\n\u003cp data-start=\"7044\" data-end=\"7069\"\u003e\u003cstrong data-start=\"7044\" data-end=\"7060\"\u003eNoise Level:\u003c\/strong\u003e 75 dB(A)\u003c\/p\u003e\n\u003cp data-start=\"7071\" data-end=\"7106\"\u003e\u003cstrong data-start=\"7071\" data-end=\"7101\"\u003eCompressed Air Connection:\u003c\/strong\u003e 1\/2\"\u003c\/p\u003e\n\u003cp data-start=\"7108\" data-end=\"7167\"\u003e\u003cstrong data-start=\"7108\" data-end=\"7123\"\u003eDimensions:\u003c\/strong\u003e 29.1\" x 46.5\" x 43.7\" (740 x 1180 x 1110mm)\u003c\/p\u003e\n\u003cp data-start=\"7169\" data-end=\"7196\"\u003e\u003cstrong data-start=\"7169\" data-end=\"7180\"\u003eWeight:\u003c\/strong\u003e 401 lbs. (182 kg.)\u003c\/p\u003e\n\u003cp data-start=\"7198\" data-end=\"7289\"\u003e*Verify final electrical configuration for North American installations before publication.\u003c\/p\u003e\n\u003chr data-start=\"7291\" data-end=\"7294\"\u003e\n\u003ch2 data-section-id=\"1xfdujf\" data-start=\"7296\" data-end=\"7333\"\u003eImportant Operating Considerations\u003c\/h2\u003e\n\u003cp data-start=\"7335\" data-end=\"7368\"\u003eThe UNI 3.2.2 W3 is designed for:\u003c\/p\u003e\n\u003cul data-start=\"7370\" data-end=\"7522\"\u003e\n\u003cli data-section-id=\"mola8r\" data-start=\"7370\" data-end=\"7390\"\u003eDry welding fumes.\u003c\/li\u003e\n\u003cli data-section-id=\"1o2i76u\" data-start=\"7391\" data-end=\"7407\"\u003eGrinding dust.\u003c\/li\u003e\n\u003cli data-section-id=\"lk6x8c\" data-start=\"7408\" data-end=\"7444\"\u003eManual plasma cutting particulate.\u003c\/li\u003e\n\u003cli data-section-id=\"1ycvy3h\" data-start=\"7445\" data-end=\"7485\"\u003eMulti-station production environments.\u003c\/li\u003e\n\u003cli data-section-id=\"xb3v95\" data-start=\"7486\" data-end=\"7522\"\u003eIntensive industrial applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"7524\" data-end=\"7731\"\u003eThe unit is \u003cstrong data-start=\"7536\" data-end=\"7567\"\u003enot suitable for oily fumes\u003c\/strong\u003e and is \u003cstrong data-start=\"7575\" data-end=\"7649\"\u003enot approved for use in potentially explosive or hazardous atmospheres\u003c\/strong\u003e. Operation of the automatic cleaning system requires a compressed-air connection.\u003c\/p\u003e\n\u003chr data-start=\"7733\" data-end=\"7736\"\u003e\n\u003ch2 data-section-id=\"1og2vkl\" data-start=\"7738\" data-end=\"7794\"\u003eBuilt for Flexible Multi-Station Welding Fume Control\u003c\/h2\u003e\n\u003cp data-start=\"7796\" data-end=\"8227\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe AerService UNI 3.2.2 W3 with 10' Flex Arms delivers industrial-grade welding fume extraction for facilities requiring simultaneous source capture at multiple welding stations. Combining dual-arm flexibility, automatic filter cleaning, W3-certified filtration, and advanced airflow management, this configuration provides a powerful solution for fabrication operations where productivity, adaptability, and uptime are essential.\u003c\/p\u003e","brand":"AerService (Made in Italy)","offers":[{"title":"Default Title","offer_id":62808948670623,"sku":null,"price":6595.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0100\/8271\/3696\/files\/UNI3.2.2W3.jpg?v=1780695310","url":"https:\/\/quantummachinery.com\/products\/uni-3-2-2-w3-dual-arm-self-cleaning-mobile-filter-unit-for-welding-fumes-with-10-flex-arms","provider":"QuantumMachinery","version":"1.0","type":"link"}