{"title":"Welding Fume Extractors","description":"","products":[{"product_id":"aer-110-portable-filter-unit-for-welding-fumes","title":"AER 110: Portable Filter Unit for Welding Fumes with Flex Arm","description":"\u003ch1 data-section-id=\"1tut08q\" data-start=\"439\" data-end=\"529\"\u003ePortable Welding Fume Extraction for Light-Duty Fabrication and Maintenance Applications\u003c\/h1\u003e\n\u003cp data-start=\"531\" data-end=\"1043\"\u003eThe \u003cstrong data-start=\"535\" data-end=\"557\"\u003eAerService AER 110\u003c\/strong\u003e is a compact portable welding fume extractor designed for workshops, maintenance departments, repair operations, educational facilities, and light fabrication environments requiring simple source-capture fume extraction. Built for occasional welding applications, the AER 110 provides an economical and highly portable solution for capturing welding fumes directly at the source while improving workplace air quality and operator exposure control.\u003c\/p\u003e\n\u003cp data-start=\"1045\" data-end=\"1351\"\u003eFeaturing an integrated three-stage filtration system, flexible extraction hose, and lightweight portable design, the AER 110 delivers effective filtration performance in a plug-and-play package that can be easily moved between workstations as production needs change.\u003c\/p\u003e\n\u003chr data-start=\"1353\" data-end=\"1356\"\u003e\n\u003ch2 data-section-id=\"1bv5r5t\" data-start=\"1358\" data-end=\"1404\"\u003eWhy Source Capture Welding Fume Extraction?\u003c\/h2\u003e\n\u003cp data-start=\"1406\" data-end=\"1623\"\u003eWelding fumes contain fine airborne particulate generated during the welding process. Allowing these contaminants to disperse into the work environment can negatively impact air quality and increase operator exposure.\u003c\/p\u003e\n\u003cp data-start=\"1625\" data-end=\"1670\"\u003eCapturing fumes directly at the source helps:\u003c\/p\u003e\n\u003cul data-start=\"1672\" data-end=\"1914\"\u003e\n\u003cli data-section-id=\"1mn5fw1\" data-start=\"1672\" data-end=\"1704\"\u003eImprove workplace air quality.\u003c\/li\u003e\n\u003cli data-section-id=\"qzw9su\" data-start=\"1705\" data-end=\"1750\"\u003eReduce airborne particulate concentrations.\u003c\/li\u003e\n\u003cli data-section-id=\"ux9fzm\" data-start=\"1751\" data-end=\"1778\"\u003eImprove operator comfort.\u003c\/li\u003e\n\u003cli data-section-id=\"1mryolg\" data-start=\"1779\" data-end=\"1830\"\u003eMinimize contamination of surrounding work areas.\u003c\/li\u003e\n\u003cli data-section-id=\"3pmroo\" data-start=\"1831\" data-end=\"1871\"\u003eSupport welding fume control programs.\u003c\/li\u003e\n\u003cli data-section-id=\"al5cmu\" data-start=\"1872\" data-end=\"1914\"\u003eCreate cleaner fabrication environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1916\" data-end=\"2133\"\u003eThe AerService AER 110 is designed to provide localized extraction exactly where welding fumes are generated, helping prevent contaminants from spreading throughout the workspace.\u003c\/p\u003e\n\u003chr data-start=\"2135\" data-end=\"2138\"\u003e\n\u003ch2 data-section-id=\"1rtj4iu\" data-start=\"2140\" data-end=\"2187\"\u003eDesigned for Occasional Welding Applications\u003c\/h2\u003e\n\u003cp data-start=\"2189\" data-end=\"2266\"\u003eNot every welding operation requires a large self-cleaning extraction system.\u003c\/p\u003e\n\u003cp data-start=\"2268\" data-end=\"2310\"\u003eThe AER 110 was specifically designed for:\u003c\/p\u003e\n\u003cul data-start=\"2312\" data-end=\"2509\"\u003e\n\u003cli data-section-id=\"16bvzu4\" data-start=\"2312\" data-end=\"2338\"\u003eMaintenance departments.\u003c\/li\u003e\n\u003cli data-section-id=\"jipzk1\" data-start=\"2339\" data-end=\"2356\"\u003eRepair welding.\u003c\/li\u003e\n\u003cli data-section-id=\"ggsc6y\" data-start=\"2357\" data-end=\"2379\"\u003eMobile service work.\u003c\/li\u003e\n\u003cli data-section-id=\"1k4v28s\" data-start=\"2380\" data-end=\"2411\"\u003eEducational welding programs.\u003c\/li\u003e\n\u003cli data-section-id=\"17qkqq6\" data-start=\"2412\" data-end=\"2438\"\u003eSmall fabrication shops.\u003c\/li\u003e\n\u003cli data-section-id=\"mseyqy\" data-start=\"2439\" data-end=\"2471\"\u003eIntermittent welding stations.\u003c\/li\u003e\n\u003cli data-section-id=\"d34g7g\" data-start=\"2472\" data-end=\"2509\"\u003eLight-duty production environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2511\" data-end=\"2734\"\u003eIts compact footprint and portable design allow operators to position extraction exactly where it is needed without requiring permanent ducting or centralized filtration infrastructure.\u003c\/p\u003e\n\u003chr data-start=\"2736\" data-end=\"2739\"\u003e\n\u003ch2 data-section-id=\"1w6odg8\" data-start=\"2741\" data-end=\"2773\"\u003eMulti-Stage Filtration System\u003c\/h2\u003e\n\u003cp data-start=\"2775\" data-end=\"2948\"\u003eThe AerService AER 110 utilizes a three-stage mechanical filtration design engineered to capture particulate while helping protect the primary filter from premature loading.\u003c\/p\u003e\n\u003ch3 data-section-id=\"kpe4th\" data-start=\"2950\" data-end=\"2978\"\u003eStage 1 – Spark Arrestor\u003c\/h3\u003e\n\u003cp data-start=\"2980\" data-end=\"3174\"\u003eA metallic spark arrestor provides the first level of protection by intercepting larger particles and sparks before they reach the primary filtration media.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xm8mmm\" data-start=\"3176\" data-end=\"3222\"\u003eStage 2 – High-Efficiency Cartridge Filter\u003c\/h3\u003e\n\u003cp data-start=\"3224\" data-end=\"3461\"\u003eThe primary cartridge filter is rated \u003cstrong data-start=\"3262\" data-end=\"3277\"\u003eBIA Class M\u003c\/strong\u003e with filtration efficiency exceeding \u003cstrong data-start=\"3315\" data-end=\"3322\"\u003e99%\u003c\/strong\u003e, providing effective removal of welding fume particulate generated during common welding operations.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1dipc6k\" data-start=\"3463\" data-end=\"3500\"\u003eStage 3 – Activated Carbon Filter\u003c\/h3\u003e\n\u003cp data-start=\"3502\" data-end=\"3682\"\u003eA 1 kg activated carbon stage provides additional adsorption capability for odors and gaseous contaminants associated with welding operations.\u003c\/p\u003e\n\u003chr data-start=\"3684\" data-end=\"3687\"\u003e\n\u003ch2 data-section-id=\"1wyl6mz\" data-start=\"3689\" data-end=\"3722\"\u003eFlexible Source Capture Design\u003c\/h2\u003e\n\u003cp data-start=\"3724\" data-end=\"3982\"\u003eThe AER 110 includes a flexible extraction hose with capture nozzle and magnetic positioning system, allowing operators to easily position the extraction point close to the weld zone for improved fume capture efficiency.\u003c\/p\u003e\n\u003cp data-start=\"3984\" data-end=\"4017\"\u003eThis flexible arrangement allows:\u003c\/p\u003e\n\u003cul data-start=\"4019\" data-end=\"4197\"\u003e\n\u003cli data-section-id=\"1l69zp6\" data-start=\"4019\" data-end=\"4057\"\u003eEasy positioning at the weld source.\u003c\/li\u003e\n\u003cli data-section-id=\"1cp9tve\" data-start=\"4058\" data-end=\"4083\"\u003eFast workstation setup.\u003c\/li\u003e\n\u003cli data-section-id=\"4xfdcz\" data-start=\"4084\" data-end=\"4116\"\u003eImproved operator convenience.\u003c\/li\u003e\n\u003cli data-section-id=\"1kyp221\" data-start=\"4117\" data-end=\"4160\"\u003ePortable use between multiple work areas.\u003c\/li\u003e\n\u003cli data-section-id=\"1aguy5u\" data-start=\"4161\" data-end=\"4197\"\u003eReduced installation requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4199\" data-end=\"4202\"\u003e\n\u003ch2 data-section-id=\"14c1n0\" data-start=\"4204\" data-end=\"4234\"\u003eSupported Welding Processes\u003c\/h2\u003e\n\u003cp data-start=\"4236\" data-end=\"4275\"\u003eThe AerService AER 110 is suitable for:\u003c\/p\u003e\n\u003cul data-start=\"4277\" data-end=\"4365\"\u003e\n\u003cli data-section-id=\"1l448pd\" data-start=\"4277\" data-end=\"4290\"\u003eMIG Welding\u003c\/li\u003e\n\u003cli data-section-id=\"1cggtnd\" data-start=\"4291\" data-end=\"4304\"\u003eMAG Welding\u003c\/li\u003e\n\u003cli data-section-id=\"116658u\" data-start=\"4305\" data-end=\"4329\"\u003ePulsed MIG\/MAG Welding\u003c\/li\u003e\n\u003cli data-section-id=\"qyiua0\" data-start=\"4330\" data-end=\"4343\"\u003eTIG Welding\u003c\/li\u003e\n\u003cli data-section-id=\"v9v5qy\" data-start=\"4344\" data-end=\"4365\"\u003eMMA \/ Stick Welding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4367\" data-end=\"4481\"\u003eThe unit is designed for dry welding fumes generated during these processes.\u003c\/p\u003e\n\u003chr data-start=\"4483\" data-end=\"4486\"\u003e\n\u003ch2 data-section-id=\"19vd27d\" data-start=\"4488\" data-end=\"4509\"\u003eIdeal Applications\u003c\/h2\u003e\n\u003cp data-start=\"4511\" data-end=\"4552\"\u003eThe AER 110 is an excellent solution for:\u003c\/p\u003e\n\u003cul data-start=\"4554\" data-end=\"4772\"\u003e\n\u003cli data-section-id=\"v8b3ot\" data-start=\"4554\" data-end=\"4578\"\u003eMaintenance workshops.\u003c\/li\u003e\n\u003cli data-section-id=\"1dxx9pu\" data-start=\"4579\" data-end=\"4609\"\u003eEquipment repair facilities.\u003c\/li\u003e\n\u003cli data-section-id=\"17qkqq6\" data-start=\"4610\" data-end=\"4636\"\u003eSmall fabrication shops.\u003c\/li\u003e\n\u003cli data-section-id=\"1k4v28s\" data-start=\"4637\" data-end=\"4668\"\u003eEducational welding programs.\u003c\/li\u003e\n\u003cli data-section-id=\"mseyqy\" data-start=\"4669\" data-end=\"4701\"\u003eIntermittent welding stations.\u003c\/li\u003e\n\u003cli data-section-id=\"1yq9t0k\" data-start=\"4702\" data-end=\"4736\"\u003eField service preparation areas.\u003c\/li\u003e\n\u003cli data-section-id=\"1hzv7y6\" data-start=\"4737\" data-end=\"4772\"\u003eLight manufacturing environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4774\" data-end=\"4777\"\u003e\n\u003ch2 data-section-id=\"1hevpv8\" data-start=\"4779\" data-end=\"4805\"\u003eWho Is the AER 110 For?\u003c\/h2\u003e\n\u003cp data-start=\"4807\" data-end=\"4851\"\u003eThe AER 110 is ideal for organizations that:\u003c\/p\u003e\n\u003cul data-start=\"4853\" data-end=\"5138\"\u003e\n\u003cli data-section-id=\"1t8la5t\" data-start=\"4853\" data-end=\"4894\"\u003ePerform welding on an occasional basis.\u003c\/li\u003e\n\u003cli data-section-id=\"1x0pqc0\" data-start=\"4895\" data-end=\"4942\"\u003eNeed a low-cost portable extraction solution.\u003c\/li\u003e\n\u003cli data-section-id=\"4go36w\" data-start=\"4943\" data-end=\"4983\"\u003eRequire mobility between workstations.\u003c\/li\u003e\n\u003cli data-section-id=\"1ivmkr8\" data-start=\"4984\" data-end=\"5011\"\u003eHave limited floor space.\u003c\/li\u003e\n\u003cli data-section-id=\"16kyvy5\" data-start=\"5012\" data-end=\"5069\"\u003eDo not require a large self-cleaning extraction system.\u003c\/li\u003e\n\u003cli data-section-id=\"1qvr1zz\" data-start=\"5070\" data-end=\"5138\"\u003eNeed localized source capture for intermittent welding activities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5140\" data-end=\"5143\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"5145\" data-end=\"5160\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"5162\" data-end=\"5573\"\u003e\n\u003cli data-section-id=\"1ylhlvk\" data-start=\"5162\" data-end=\"5188\"\u003eCompact portable design.\u003c\/li\u003e\n\u003cli data-section-id=\"1bmbo3l\" data-start=\"5189\" data-end=\"5222\"\u003eLightweight 19 kg construction.\u003c\/li\u003e\n\u003cli data-section-id=\"auw0ls\" data-start=\"5223\" data-end=\"5261\"\u003eIntegrated flexible extraction hose.\u003c\/li\u003e\n\u003cli data-section-id=\"vr2pfw\" data-start=\"5262\" data-end=\"5299\"\u003eMagnetic nozzle positioning system.\u003c\/li\u003e\n\u003cli data-section-id=\"1vu43b0\" data-start=\"5300\" data-end=\"5332\"\u003eThree-stage filtration system.\u003c\/li\u003e\n\u003cli data-section-id=\"ruuhis\" data-start=\"5333\" data-end=\"5359\"\u003eMetallic spark arrestor.\u003c\/li\u003e\n\u003cli data-section-id=\"1r0q0ku\" data-start=\"5360\" data-end=\"5395\"\u003eBIA Class M cartridge filtration.\u003c\/li\u003e\n\u003cli data-section-id=\"fzswms\" data-start=\"5396\" data-end=\"5432\"\u003eActivated carbon filtration stage.\u003c\/li\u003e\n\u003cli data-section-id=\"1xxanzz\" data-start=\"5433\" data-end=\"5448\"\u003e1.1 kW motor.\u003c\/li\u003e\n\u003cli data-section-id=\"gwvnf6\" data-start=\"5449\" data-end=\"5475\"\u003ePlug-and-play operation.\u003c\/li\u003e\n\u003cli data-section-id=\"7xr54h\" data-start=\"5476\" data-end=\"5509\"\u003eSuitable for dry welding fumes.\u003c\/li\u003e\n\u003cli data-section-id=\"1c0b4g0\" data-start=\"5510\" data-end=\"5573\"\u003eSimple ON\/OFF controls.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5575\" data-end=\"5578\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"5580\" data-end=\"5607\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"5609\" data-end=\"6033\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"5609\" data-end=\"5636\"\u003e\n\u003ctr data-start=\"5609\" data-end=\"5636\"\u003e\n\u003cth data-start=\"5609\" data-end=\"5625\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"5625\" data-end=\"5636\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eAER 110\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"5665\" data-end=\"6033\"\u003e\n\u003ctr data-start=\"5665\" data-end=\"5692\"\u003e\n\u003ctd data-start=\"5665\" data-end=\"5680\" data-col-size=\"sm\"\u003eFan Capacity\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"5680\" data-end=\"5692\"\u003e250 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5693\" data-end=\"5727\"\u003e\n\u003ctd data-start=\"5693\" data-end=\"5715\" data-col-size=\"sm\"\u003eExtraction Capacity\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"5715\" data-end=\"5727\"\u003e110 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5728\" data-end=\"5772\"\u003e\n\u003ctd data-start=\"5728\" data-end=\"5752\" data-col-size=\"sm\"\u003eFiltration Efficiency\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"5752\" data-end=\"5772\"\u003eBIA Class M \u0026gt;99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5773\" data-end=\"5809\"\u003e\n\u003ctd data-start=\"5773\" data-end=\"5801\" data-col-size=\"sm\"\u003eActivated Carbon Capacity\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"5801\" data-end=\"5809\"\u003e2.2 lbs. (1 kg.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5810\" data-end=\"5834\"\u003e\n\u003ctd data-start=\"5810\" data-end=\"5824\" data-col-size=\"sm\"\u003eMotor Power\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"5824\" data-end=\"5834\"\u003e1.1 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5835\" data-end=\"5860\"\u003e\n\u003ctd data-start=\"5835\" data-end=\"5845\" data-col-size=\"sm\"\u003eVoltage\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"5845\" data-end=\"5860\"\u003e220V \/ 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5861\" data-end=\"5887\"\u003e\n\u003ctd data-start=\"5861\" data-end=\"5875\" data-col-size=\"sm\"\u003eNoise Level\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"5875\" data-end=\"5887\"\u003e80 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5888\" data-end=\"5914\"\u003e\n\u003ctd data-start=\"5888\" data-end=\"5904\" data-col-size=\"sm\"\u003eHose Diameter\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"5904\" data-end=\"5914\"\u003eØ 1.96\" (50mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5915\" data-end=\"5936\"\u003e\n\u003ctd data-start=\"5915\" data-end=\"5929\" data-col-size=\"sm\"\u003eHose Length\u003c\/td\u003e\n\u003ctd data-start=\"5929\" data-end=\"5936\" data-col-size=\"sm\"\u003e118\" (3m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5937\" data-end=\"5972\"\u003e\n\u003ctd data-start=\"5937\" data-end=\"5950\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-start=\"5950\" data-end=\"5972\" data-col-size=\"sm\"\u003e8.4\" x 21.3\" x 10.2\" (214 × 542 × 261mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5973\" data-end=\"6033\"\u003e\n\u003ctd data-start=\"5973\" data-end=\"5982\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"5982\" data-end=\"5990\" data-col-size=\"sm\"\u003e42 lbs. (19 kg.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"6035\" data-end=\"6038\"\u003e\n\u003ch2 data-section-id=\"1xfdujf\" data-start=\"6040\" data-end=\"6077\"\u003eImportant Operating Considerations\u003c\/h2\u003e\n\u003cp data-start=\"6079\" data-end=\"6118\"\u003eThe AerService AER 110 is designed for:\u003cbr\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e- Dry welding fumes only.\u003cbr\u003e\u003c\/span\u003e- Light-duty and occasional use applications.\u003c\/p\u003e\n\u003cp data-start=\"6193\" data-end=\"6359\"\u003eThe unit is \u003cstrong data-start=\"6205\" data-end=\"6236\"\u003enot suitable for oily fumes\u003c\/strong\u003e and is \u003cstrong data-start=\"6244\" data-end=\"6318\"\u003enot approved for use in potentially explosive or hazardous atmospheres\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"6361\" data-end=\"6364\"\u003e\n\u003ch2 data-section-id=\"243f9p\" data-start=\"6366\" data-end=\"6408\"\u003eBuilt for Portable Welding Fume Control\u003c\/h2\u003e\n\u003cp data-start=\"6410\" data-end=\"6880\"\u003eThe AerService AER 110 provides a practical and economical solution for facilities requiring portable welding fume extraction without the complexity of larger mobile or centralized systems. Combining effective source capture, multi-stage filtration, and compact portability, the AER 110 helps improve air quality and operator comfort in light-duty welding environments while remaining easy to deploy wherever extraction is needed.\u003c\/p\u003e","brand":"AerService (Made in Italy)","offers":[{"title":"Default Title","offer_id":62804110835871,"sku":null,"price":995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0100\/8271\/3696\/files\/aer-110-portable-filter-unit-for-welding-fumes-welding-fume-extraction-systems-quantum-machinery-group-usa-6378158.jpg?v=1780488066"},{"product_id":"mono-plus-w3-mobile-filter-unit-for-welding-fumes","title":"MONO PLUS W3: Mobile Filter Unit for Welding Fumes","description":"\u003ch2 data-section-id=\"jgfgv6\" data-start=\"54\" data-end=\"137\"\u003eMobile Welding Fume Extraction for Daily Fabrication and Production Applications\u003c\/h2\u003e\n\u003cp data-start=\"139\" data-end=\"604\"\u003eThe \u003cstrong data-start=\"143\" data-end=\"170\"\u003eAerService MONO PLUS W3\u003c\/strong\u003e is a mobile welding fume extraction system designed for fabrication shops and production environments requiring reliable source-capture extraction for daily welding operations. Built for medium-duty welding applications, the MONO PLUS W3 combines high-efficiency W3-certified filtration, mobile workstation flexibility, and simplified filter maintenance in a compact, professional-grade package.\u003c\/p\u003e\n\u003cp data-start=\"606\" data-end=\"933\"\u003eDesigned to bridge the gap between portable entry-level extractors and fully automatic self-cleaning systems, the MONO PLUS W3 delivers professional welding fume control for facilities that require dependable daily operation without the added complexity of compressed-air cleaning systems.\u003c\/p\u003e\n\u003chr data-start=\"935\" data-end=\"938\"\u003e\n\u003ch2 data-section-id=\"1bv5r5t\" data-start=\"940\" data-end=\"986\"\u003eWhy Source Capture Welding Fume Extraction?\u003c\/h2\u003e\n\u003cp data-start=\"988\" data-end=\"1249\"\u003eWelding fumes contain fine airborne particulate that can spread throughout the workplace if not captured at the source. Effective source-capture extraction removes contaminants before they enter the operator's breathing zone or disperse throughout the facility.\u003c\/p\u003e\n\u003cp data-start=\"1251\" data-end=\"1296\"\u003eCapturing fumes directly at the source helps:\u003c\/p\u003e\n\u003cul data-start=\"1298\" data-end=\"1586\"\u003e\n\u003cli data-section-id=\"1mn5fw1\" data-start=\"1298\" data-end=\"1330\"\u003eImprove workplace air quality.\u003c\/li\u003e\n\u003cli data-section-id=\"6i20mt\" data-start=\"1331\" data-end=\"1383\"\u003eReduce operator exposure to airborne contaminants.\u003c\/li\u003e\n\u003cli data-section-id=\"12uea0\" data-start=\"1384\" data-end=\"1427\"\u003eMaintain cleaner production environments.\u003c\/li\u003e\n\u003cli data-section-id=\"exidex\" data-start=\"1428\" data-end=\"1488\"\u003eReduce particulate accumulation on equipment and surfaces.\u003c\/li\u003e\n\u003cli data-section-id=\"1ep3n9k\" data-start=\"1489\" data-end=\"1538\"\u003eSupport facility health and safety initiatives.\u003c\/li\u003e\n\u003cli data-section-id=\"3h9axo\" data-start=\"1539\" data-end=\"1586\"\u003eImprove overall fabrication shop cleanliness.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1588\" data-end=\"1813\"\u003eThe MONO PLUS W3 is designed to provide effective source-capture extraction directly at the weld zone, helping control fumes before they become an environmental issue within the facility.\u003c\/p\u003e\n\u003chr data-start=\"1815\" data-end=\"1818\"\u003e\n\u003ch2 data-section-id=\"165rnr\" data-start=\"1820\" data-end=\"1862\"\u003eDesigned for Daily Welding Applications\u003c\/h2\u003e\n\u003cp data-start=\"1864\" data-end=\"2062\"\u003eThe MONO PLUS W3 is engineered for facilities performing welding throughout the workday where a portable extractor may be insufficient but a fully automatic self-cleaning system is not yet required.\u003c\/p\u003e\n\u003cp data-start=\"2064\" data-end=\"2091\"\u003eIdeal applications include:\u003c\/p\u003e\n\u003cul data-start=\"2093\" data-end=\"2291\"\u003e\n\u003cli data-section-id=\"1l12r2p\" data-start=\"2093\" data-end=\"2113\"\u003eFabrication shops.\u003c\/li\u003e\n\u003cli data-section-id=\"6zw4md\" data-start=\"2114\" data-end=\"2141\"\u003eManufacturing facilities.\u003c\/li\u003e\n\u003cli data-section-id=\"13ia2k0\" data-start=\"2142\" data-end=\"2168\"\u003eMetalworking operations.\u003c\/li\u003e\n\u003cli data-section-id=\"16bvzu4\" data-start=\"2169\" data-end=\"2195\"\u003eMaintenance departments.\u003c\/li\u003e\n\u003cli data-section-id=\"1k4v28s\" data-start=\"2196\" data-end=\"2227\"\u003eEducational welding programs.\u003c\/li\u003e\n\u003cli data-section-id=\"1ydpdjp\" data-start=\"2228\" data-end=\"2257\"\u003eRepair and service centers.\u003c\/li\u003e\n\u003cli data-section-id=\"11h9kun\" data-start=\"2258\" data-end=\"2291\"\u003eDedicated welding workstations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2293\" data-end=\"2465\"\u003eIts mobile design allows the system to be repositioned between work areas while maintaining professional-grade filtration performance.\u003c\/p\u003e\n\u003chr data-start=\"2467\" data-end=\"2470\"\u003e\n\u003ch2 data-section-id=\"bafxwr\" data-start=\"2472\" data-end=\"2510\"\u003eW3-Certified Filtration Performance\u003c\/h2\u003e\n\u003cp data-start=\"2512\" data-end=\"2764\"\u003eThe MONO PLUS W3 is certified to \u003cstrong data-start=\"2545\" data-end=\"2572\"\u003eW3 filtration standards\u003c\/strong\u003e with filtration efficiency exceeding \u003cstrong data-start=\"2610\" data-end=\"2617\"\u003e99%\u003c\/strong\u003e, making it suitable for welding fume extraction applications requiring high-performance particulate removal.\u003c\/p\u003e\n\u003cp data-start=\"2766\" data-end=\"2797\"\u003eThe filtration system includes:\u003c\/p\u003e\n\u003ch3 data-section-id=\"12lt8oo\" data-start=\"2799\" data-end=\"2829\"\u003eStage 1 – Spark Protection\u003c\/h3\u003e\n\u003cp data-start=\"2831\" data-end=\"3008\"\u003eAn integrated spark trap helps protect the primary filtration media from sparks and larger particulate generated during welding operations.\u003c\/p\u003e\n\u003ch3 data-section-id=\"o4po9i\" data-start=\"3010\" data-end=\"3060\"\u003eStage 2 – High-Efficiency Cartridge Filtration\u003c\/h3\u003e\n\u003cp data-start=\"3062\" data-end=\"3282\"\u003eThe primary cartridge filter utilizes \u003cstrong data-start=\"3100\" data-end=\"3143\"\u003eSintexx Plus nanofiber filtration media\u003c\/strong\u003e designed to provide high filtration efficiency while maximizing filter life and airflow performance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1szs22u\" data-start=\"3284\" data-end=\"3315\"\u003eStage 3 – Safety Filtration\u003c\/h3\u003e\n\u003cp data-start=\"3317\" data-end=\"3480\"\u003eA secondary safety filter helps provide additional protection while maintaining clean air recirculation within the workspace.\u003c\/p\u003e\n\u003chr data-start=\"3482\" data-end=\"3485\"\u003e\n\u003ch2 data-section-id=\"xxj7li\" data-start=\"3487\" data-end=\"3513\"\u003eEasy Filter Maintenance\u003c\/h2\u003e\n\u003cp data-start=\"3515\" data-end=\"3605\"\u003eOne of the key advantages of the MONO PLUS W3 is its simplified filter maintenance system.\u003c\/p\u003e\n\u003cp data-start=\"3607\" data-end=\"3624\"\u003eFeatures include:\u003c\/p\u003e\n\u003cul data-start=\"3626\" data-end=\"3821\"\u003e\n\u003cli data-section-id=\"d2a58u\" data-start=\"3626\" data-end=\"3661\"\u003eDifferential pressure monitoring.\u003c\/li\u003e\n\u003cli data-section-id=\"e5yl6c\" data-start=\"3662\" data-end=\"3685\"\u003eClogged filter alarm.\u003c\/li\u003e\n\u003cli data-section-id=\"zj3vvp\" data-start=\"3686\" data-end=\"3719\"\u003eEasy-access filter compartment.\u003c\/li\u003e\n\u003cli data-section-id=\"41k9fm\" data-start=\"3720\" data-end=\"3771\"\u003eManual filter cleaning without cartridge removal.\u003c\/li\u003e\n\u003cli data-section-id=\"19lb2gp\" data-start=\"3772\" data-end=\"3821\"\u003eDust collection drawer for simplified disposal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3823\" data-end=\"3939\"\u003eThis design helps reduce maintenance time while maximizing operational uptime.\u003c\/p\u003e\n\u003chr data-start=\"3941\" data-end=\"3944\"\u003e\n\u003ch2 data-section-id=\"4lj66i\" data-start=\"3946\" data-end=\"3994\"\u003eEnvironmentally Responsible Filter Technology\u003c\/h2\u003e\n\u003cp data-start=\"3996\" data-end=\"4158\"\u003eThe MONO PLUS W3 utilizes \u003cstrong data-start=\"4022\" data-end=\"4051\"\u003eSintexx Plus filter media\u003c\/strong\u003e, designed to provide excellent filtration performance while reducing overall filter material requirements.\u003c\/p\u003e\n\u003cp data-start=\"4160\" data-end=\"4177\"\u003eBenefits include:\u003c\/p\u003e\n\u003cul data-start=\"4179\" data-end=\"4329\"\u003e\n\u003cli data-section-id=\"c98dm\" data-start=\"4179\" data-end=\"4208\"\u003eHigh-efficiency filtration.\u003c\/li\u003e\n\u003cli data-section-id=\"1jzn5k7\" data-start=\"4209\" data-end=\"4232\"\u003eExtended filter life.\u003c\/li\u003e\n\u003cli data-section-id=\"1hn8nh7\" data-start=\"4233\" data-end=\"4271\"\u003eReduced filter surface requirements.\u003c\/li\u003e\n\u003cli data-section-id=\"jakotk\" data-start=\"4272\" data-end=\"4303\"\u003eImproved airflow performance.\u003c\/li\u003e\n\u003cli data-section-id=\"1k2nn7p\" data-start=\"4304\" data-end=\"4329\"\u003ePTFE-free construction.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4331\" data-end=\"4538\"\u003eAerService specifically notes that the media achieves performance with 20–30% less filtration surface area than many traditional solutions while avoiding PTFE materials.\u003c\/p\u003e\n\u003chr data-start=\"4540\" data-end=\"4543\"\u003e\n\u003ch2 data-section-id=\"tejv06\" data-start=\"4545\" data-end=\"4582\"\u003eFlexible Extraction Configurations\u003c\/h2\u003e\n\u003cp data-start=\"4584\" data-end=\"4661\"\u003eThe MONO PLUS W3 can be configured to meet a variety of welding applications.\u003c\/p\u003e\n\u003cp data-start=\"4663\" data-end=\"4689\"\u003eAvailable options include:\u003c\/p\u003e\n\u003cul data-start=\"4691\" data-end=\"4889\"\u003e\n\u003cli data-section-id=\"1nhcwwe\" data-start=\"4691\" data-end=\"4721\"\u003eArticulated extraction arms.\u003c\/li\u003e\n\u003cli data-section-id=\"16wnzqf\" data-start=\"4722\" data-end=\"4749\"\u003eFlexible hose extraction.\u003c\/li\u003e\n\u003cli data-section-id=\"b4ntra\" data-start=\"4750\" data-end=\"4778\"\u003eIntegrated welding tables.\u003c\/li\u003e\n\u003cli data-section-id=\"t5c9ya\" data-start=\"4779\" data-end=\"4818\"\u003eWelding tables with UV light shields.\u003c\/li\u003e\n\u003cli data-section-id=\"lrdh7h\" data-start=\"4819\" data-end=\"4852\"\u003eHood-mounted LED lighting kits.\u003c\/li\u003e\n\u003cli data-section-id=\"29xde1\" data-start=\"4853\" data-end=\"4889\"\u003eAdditional spark arrestor filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4891\" data-end=\"5041\"\u003eThis flexibility allows users to tailor the system to specific welding processes and workstation requirements.\u003c\/p\u003e\n\u003chr data-start=\"5043\" data-end=\"5046\"\u003e\n\u003ch2 data-section-id=\"14c1n0\" data-start=\"5048\" data-end=\"5078\"\u003eSupported Welding Processes\u003c\/h2\u003e\n\u003cp data-start=\"5080\" data-end=\"5113\"\u003eThe MONO PLUS W3 is suitable for:\u003c\/p\u003e\n\u003cul data-start=\"5115\" data-end=\"5203\"\u003e\n\u003cli data-section-id=\"1l448pd\" data-start=\"5115\" data-end=\"5128\"\u003eMIG Welding\u003c\/li\u003e\n\u003cli data-section-id=\"1cggtnd\" data-start=\"5129\" data-end=\"5142\"\u003eMAG Welding\u003c\/li\u003e\n\u003cli data-section-id=\"116658u\" data-start=\"5143\" data-end=\"5167\"\u003ePulsed MIG\/MAG Welding\u003c\/li\u003e\n\u003cli data-section-id=\"qyiua0\" data-start=\"5168\" data-end=\"5181\"\u003eTIG Welding\u003c\/li\u003e\n\u003cli data-section-id=\"v9v5qy\" data-start=\"5182\" data-end=\"5203\"\u003eMMA \/ Stick Welding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5205\" data-end=\"5346\"\u003eThe system is designed for dry welding fumes and is not intended for oily smoke or mist applications.\u003c\/p\u003e\n\u003chr data-start=\"5348\" data-end=\"5351\"\u003e\n\u003ch2 data-section-id=\"19vd27d\" data-start=\"5353\" data-end=\"5374\"\u003eIdeal Applications\u003c\/h2\u003e\n\u003cp data-start=\"5376\" data-end=\"5422\"\u003eThe MONO PLUS W3 is an excellent solution for:\u003c\/p\u003e\n\u003cul data-start=\"5424\" data-end=\"5651\"\u003e\n\u003cli data-section-id=\"1tz13nd\" data-start=\"5424\" data-end=\"5455\"\u003eDaily fabrication operations.\u003c\/li\u003e\n\u003cli data-section-id=\"5e5ydl\" data-start=\"5456\" data-end=\"5486\"\u003eManufacturing welding cells.\u003c\/li\u003e\n\u003cli data-section-id=\"wek2ao\" data-start=\"5487\" data-end=\"5513\"\u003eMetal fabrication shops.\u003c\/li\u003e\n\u003cli data-section-id=\"18kseu1\" data-start=\"5514\" data-end=\"5548\"\u003eProduction welding environments.\u003c\/li\u003e\n\u003cli data-section-id=\"16bvzu4\" data-start=\"5549\" data-end=\"5575\"\u003eMaintenance departments.\u003c\/li\u003e\n\u003cli data-section-id=\"ggvaxi\" data-start=\"5576\" data-end=\"5608\"\u003eTechnical training facilities.\u003c\/li\u003e\n\u003cli data-section-id=\"1uis2tg\" data-start=\"5609\" data-end=\"5651\"\u003eGeneral industrial welding applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5653\" data-end=\"5656\"\u003e\n\u003ch2 data-section-id=\"vv680f\" data-start=\"5658\" data-end=\"5689\"\u003eWho Is the MONO PLUS W3 For?\u003c\/h2\u003e\n\u003cp data-start=\"5691\" data-end=\"5740\"\u003eThe MONO PLUS W3 is ideal for organizations that:\u003c\/p\u003e\n\u003cul data-start=\"5742\" data-end=\"6013\"\u003e\n\u003cli data-section-id=\"1lt6fuk\" data-start=\"5742\" data-end=\"5783\"\u003ePerform welding throughout the workday.\u003c\/li\u003e\n\u003cli data-section-id=\"1q2emsm\" data-start=\"5784\" data-end=\"5829\"\u003eRequire professional-grade fume extraction.\u003c\/li\u003e\n\u003cli data-section-id=\"164tvrj\" data-start=\"5830\" data-end=\"5867\"\u003eNeed mobility between workstations.\u003c\/li\u003e\n\u003cli data-section-id=\"sc1rdw\" data-start=\"5868\" data-end=\"5911\"\u003eWant W3-certified filtration performance.\u003c\/li\u003e\n\u003cli data-section-id=\"1rfu461\" data-start=\"5912\" data-end=\"5954\"\u003ePrefer simple manual filter maintenance.\u003c\/li\u003e\n\u003cli data-section-id=\"y1obb1\" data-start=\"5955\" data-end=\"6013\"\u003eDo not require automatic compressed-air filter cleaning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6015\" data-end=\"6018\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"6020\" data-end=\"6035\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"6037\" data-end=\"6528\"\u003e\n\u003cli data-section-id=\"1jopxsz\" data-start=\"6037\" data-end=\"6091\"\u003eW3-certified filtration efficiency greater than 99%.\u003c\/li\u003e\n\u003cli data-section-id=\"1jon0c\" data-start=\"6092\" data-end=\"6121\"\u003eMobile extraction platform.\u003c\/li\u003e\n\u003cli data-section-id=\"8yzbbk\" data-start=\"6122\" data-end=\"6159\"\u003eHigh-capacity cartridge filtration.\u003c\/li\u003e\n\u003cli data-section-id=\"1d29ih\" data-start=\"6160\" data-end=\"6198\"\u003eSintexx Plus nanofiber filter media.\u003c\/li\u003e\n\u003cli data-section-id=\"4vbdgd\" data-start=\"6199\" data-end=\"6223\"\u003eIntegrated spark trap.\u003c\/li\u003e\n\u003cli data-section-id=\"d2a58u\" data-start=\"6224\" data-end=\"6259\"\u003eDifferential pressure monitoring.\u003c\/li\u003e\n\u003cli data-section-id=\"e5yl6c\" data-start=\"6260\" data-end=\"6283\"\u003eClogged filter alarm.\u003c\/li\u003e\n\u003cli data-section-id=\"8xvrz2\" data-start=\"6284\" data-end=\"6321\"\u003eEasy-access manual filter cleaning.\u003c\/li\u003e\n\u003cli data-section-id=\"11hhk29\" data-start=\"6322\" data-end=\"6347\"\u003eDust collection drawer.\u003c\/li\u003e\n\u003cli data-section-id=\"1q8rizx\" data-start=\"6348\" data-end=\"6361\"\u003eHour meter.\u003c\/li\u003e\n\u003cli data-section-id=\"q02fds\" data-start=\"6362\" data-end=\"6393\"\u003eMain power disconnect switch.\u003c\/li\u003e\n\u003cli data-section-id=\"1llce5w\" data-start=\"6394\" data-end=\"6455\"\u003eCompatible with extraction arms, hoses, and welding tables.\u003c\/li\u003e\n\u003cli data-section-id=\"wpbuur\" data-start=\"6456\" data-end=\"6528\"\u003ePTFE-free filter media design.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6530\" data-end=\"6533\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"6535\" data-end=\"6562\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"6564\" data-end=\"7034\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"6564\" data-end=\"6596\"\u003e\n\u003ctr data-start=\"6564\" data-end=\"6596\"\u003e\n\u003cth data-start=\"6564\" data-end=\"6580\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"6580\" data-end=\"6596\" data-col-size=\"md\" class=\"last:pe-10\"\u003eMONO PLUS W3\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"6629\" data-end=\"7034\"\u003e\n\u003ctr data-start=\"6629\" data-end=\"6670\"\u003e\n\u003ctd data-start=\"6629\" data-end=\"6644\" data-col-size=\"sm\"\u003eFan Capacity\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"6644\" data-end=\"6670\"\u003e1,471 CFM (2,500 m³\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6671\" data-end=\"6717\"\u003e\n\u003ctd data-start=\"6671\" data-end=\"6693\" data-col-size=\"sm\"\u003eExtraction Capacity\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"6693\" data-end=\"6717\"\u003e647 CFM (1,100 m³\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6718\" data-end=\"6763\"\u003e\n\u003ctd data-start=\"6718\" data-end=\"6742\" data-col-size=\"sm\"\u003eFiltration Efficiency\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"6742\" data-end=\"6763\"\u003eW3 Certified \u0026gt;99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6764\" data-end=\"6803\"\u003e\n\u003ctd data-start=\"6764\" data-end=\"6778\" data-col-size=\"sm\"\u003eFilter Area\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"6778\" data-end=\"6803\"\u003e67.8 sq. ft. (6.3 m²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6804\" data-end=\"6845\"\u003e\n\u003ctd data-start=\"6804\" data-end=\"6819\" data-col-size=\"sm\"\u003eFilter Media\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"6819\" data-end=\"6845\"\u003eSintexx Plus Nanofiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6846\" data-end=\"6879\"\u003e\n\u003ctd data-start=\"6846\" data-end=\"6860\" data-col-size=\"sm\"\u003eMotor Power\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"6860\" data-end=\"6879\"\u003e1.5 HP (1.1 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6880\" data-end=\"6916\"\u003e\n\u003ctd data-start=\"6880\" data-end=\"6890\" data-col-size=\"sm\"\u003eVoltage\u003c\/td\u003e\n\u003ctd data-start=\"6890\" data-end=\"6916\" data-col-size=\"md\"\u003e230V \/ 1 Phase \/ 50Hz*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6917\" data-end=\"6943\"\u003e\n\u003ctd data-start=\"6917\" data-end=\"6931\" data-col-size=\"sm\"\u003eNoise Level\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"6931\" data-end=\"6943\"\u003e75 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6944\" data-end=\"7004\"\u003e\n\u003ctd data-start=\"6944\" data-end=\"6957\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"6957\" data-end=\"7004\"\u003e22.1 x 30.1 x 29.1 in. (561 x 765 x 740 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7005\" data-end=\"7034\"\u003e\n\u003ctd data-start=\"7005\" data-end=\"7014\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7014\" data-end=\"7034\"\u003e130 lbs. (59 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"7036\" data-end=\"7216\"\u003e*Verify final electrical configuration for North American installations before publication. Catalog specification is 230V \/ 1 Phase \/ 50Hz.\u003c\/p\u003e\n\u003chr data-start=\"7218\" data-end=\"7221\"\u003e\n\u003ch2 data-section-id=\"1xfdujf\" data-start=\"7223\" data-end=\"7260\"\u003eImportant Operating Considerations\u003c\/h2\u003e\n\u003cp data-start=\"7262\" data-end=\"7295\"\u003eThe MONO PLUS W3 is designed for:\u003c\/p\u003e\n\u003cul data-start=\"7297\" data-end=\"7392\"\u003e\n\u003cli data-section-id=\"13hul2n\" data-start=\"7297\" data-end=\"7322\"\u003eDry welding fumes only.\u003c\/li\u003e\n\u003cli data-section-id=\"1rfuex8\" data-start=\"7323\" data-end=\"7352\"\u003eDaily welding applications.\u003c\/li\u003e\n\u003cli data-section-id=\"1co9ycs\" data-start=\"7353\" data-end=\"7392\"\u003eMedium-duty fabrication environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"7394\" data-end=\"7560\"\u003eThe unit is \u003cstrong data-start=\"7406\" data-end=\"7437\"\u003enot suitable for oily fumes\u003c\/strong\u003e and is \u003cstrong data-start=\"7445\" data-end=\"7519\"\u003enot approved for use in potentially explosive or hazardous atmospheres\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"7562\" data-end=\"7565\"\u003e\n\u003ch2 data-section-id=\"13kgqb0\" data-start=\"7567\" data-end=\"7619\"\u003eBuilt for Professional Daily Welding Fume Control\u003c\/h2\u003e\n\u003cp data-start=\"7621\" data-end=\"8117\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe AerService MONO PLUS W3 delivers professional-grade welding fume extraction for fabrication facilities requiring reliable daily operation, high-efficiency W3-certified filtration, and simplified maintenance. Combining mobile flexibility, effective source capture, and proven filtration technology, the MONO PLUS W3 provides an ideal solution for welding shops seeking dependable fume control without the complexity of a self-cleaning extraction system.\u003c\/p\u003e","brand":"AerService (Made in Italy)","offers":[{"title":"Default Title","offer_id":62805869330591,"sku":null,"price":2775.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0100\/8271\/3696\/files\/mono-plus-w3-mobile-filter-unit-for-welding-fumes-welding-fume-extraction-systems-quantum-machinery-group-usa-4265806.jpg?v=1780488066"},{"product_id":"uni-2h-professional-mobile-welding-fume-extraction-system","title":"UNI 2H: Professional Mobile Welding Fume Extraction System","description":"\u003ch1\u003eUNI 2H: Professional Mobile Filter Unit – Mechanical Filtration\u003c\/h1\u003e\n\u003ch2\u003eProfessional Welding Fume Extraction for Daily Industrial Applications\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAerService UNI 2H\u003c\/strong\u003e is a professional-grade mobile welding fume extraction system designed for fabrication facilities requiring enhanced filtration performance, larger filter capacity, and advanced monitoring features for continuous daily operation. Engineered for industrial welding environments, the UNI 2H delivers high-efficiency multi-stage mechanical filtration while providing the airflow, filtration surface area, and operational control necessary for demanding fabrication applications.\u003c\/p\u003e\n\u003cp\u003eFeaturing a digital control system, large-capacity filtration package, alarm monitoring, and optional HEPA and activated carbon filtration upgrades, the UNI 2H represents a significant step up from entry-level mobile extractors for facilities requiring greater filtration capacity and application flexibility.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eWhy Professional Source Capture Matters\u003c\/h2\u003e\n\u003cp\u003eIn production welding environments, airborne contaminants can quickly accumulate throughout the facility if fumes are not captured directly at the source.\u003c\/p\u003e\n\u003cp\u003eEffective source-capture extraction helps:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eImprove workplace air quality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReduce operator exposure to welding fumes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMinimize contamination of equipment and finished products.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupport facility safety and compliance initiatives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eImprove overall cleanliness within fabrication areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReduce airborne particulate migration throughout the shop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe UNI 2H is designed to remove contaminants at the point of generation before they disperse into the work environment.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eDesigned for Regular Daily Welding Operations\u003c\/h2\u003e\n\u003cp\u003eThe UNI 2H is engineered for facilities that perform welding throughout the day and require greater filtration capacity than compact mobile extraction systems.\u003c\/p\u003e\n\u003cp\u003eIdeal applications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFabrication facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManufacturing plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHeavy industrial welding operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintenance departments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical training centers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduction welding workstations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMetal fabrication shops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts larger filtration package and professional control system make it well suited for facilities operating multiple shifts or performing continuous daily welding activities.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eThree-Stage Mechanical Filtration System\u003c\/h2\u003e\n\u003cp\u003eThe UNI 2H utilizes a multi-stage filtration system designed to maximize particulate capture while protecting the primary filter from premature loading.\u003c\/p\u003e\n\u003ch3\u003eStage 1 – Spark Arrestor\u003c\/h3\u003e\n\u003cp\u003eAn integrated spark arrestor captures sparks and larger particulate before they reach the primary filtration stages.\u003c\/p\u003e\n\u003ch3\u003eStage 2 – Pre-Filter\u003c\/h3\u003e\n\u003cp\u003eThe intermediate filter stage removes larger airborne particulate and helps extend the service life of the final filtration stage.\u003c\/p\u003e\n\u003ch3\u003eStage 3 – High-Efficiency Main Filter\u003c\/h3\u003e\n\u003cp\u003eThe primary filtration stage utilizes an \u003cstrong\u003eE12-rated pocket filter\u003c\/strong\u003e providing filtration efficiency greater than \u003cstrong\u003e99.5%\u003c\/strong\u003e, delivering high-performance welding fume filtration for industrial applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eAdvanced Digital Control System\u003c\/h2\u003e\n\u003cp\u003eThe UNI 2H includes a digital control panel designed to improve system monitoring and simplify operation.\u003c\/p\u003e\n\u003cp\u003eFeatures include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMulti-language interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHour meter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlarm history log.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClogged filter alarm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem status monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese capabilities help operators monitor system performance and schedule maintenance before airflow performance is impacted.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eExpanded Filtration Options\u003c\/h2\u003e\n\u003cp\u003eThe UNI 2H can be configured with additional filtration technologies for specialized applications.\u003c\/p\u003e\n\u003cp\u003eOptional upgrades include:\u003c\/p\u003e\n\u003ch3\u003eActivated Carbon Filtration\u003c\/h3\u003e\n\u003cp\u003eOptional activated carbon filtration provides odor and gas adsorption capabilities using a 22 lb (10 kg) carbon package.\u003c\/p\u003e\n\u003ch3\u003eHEPA Filtration\u003c\/h3\u003e\n\u003cp\u003eOptional H13 and H14 filtration packages are available for applications requiring extremely high particulate removal efficiency.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eH13 \u0026gt;99.9%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eH14 \u0026gt;99.99%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecialized Carbon Media\u003c\/h3\u003e\n\u003cp\u003eOptional activated carbon media is available for applications involving amines and ammonia (NH3) contaminants.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFlexible Extraction Configurations\u003c\/h2\u003e\n\u003cp\u003eThe UNI 2H can be configured with a variety of source-capture options.\u003c\/p\u003e\n\u003cp\u003eAvailable accessories include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e5 in. (125 mm) articulated extraction arms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e6 in. (160 mm) articulated extraction arms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRigid extraction arm systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlexible hose extraction systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHood-mounted LED lighting kits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic Start\/Stop functionality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDual-arm configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis flexibility allows the system to be adapted to a wide range of welding environments and workstation layouts.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eSupported Welding Processes\u003c\/h2\u003e\n\u003cp\u003eThe UNI 2H is suitable for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMIG Welding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMAG Welding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePulsed MIG\/MAG Welding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTIG Welding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMMA \/ Stick Welding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe system is designed for dry welding fumes and is not intended for oily mist or oily smoke applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eIdeal Applications\u003c\/h2\u003e\n\u003cp\u003eThe UNI 2H is an excellent solution for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial fabrication facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManufacturing operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduction welding cells.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMetal fabrication shops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintenance and repair departments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical training facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFacilities requiring upgraded filtration efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApplications requiring optional HEPA filtration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eWho Is the UNI 2H For?\u003c\/h2\u003e\n\u003cp\u003eThe UNI 2H is ideal for organizations that:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eRequire daily welding fume extraction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNeed higher filtration efficiency than standard mobile extractors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWant digital monitoring and maintenance alerts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRequire optional HEPA or activated carbon filtration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperate demanding fabrication environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNeed a professional-grade mobile extraction solution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eProfessional mobile extraction platform.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThree-stage mechanical filtration system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eE12 filtration efficiency \u0026gt;99.5%.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge 156 sq. ft. (14.5 m²) filter surface area.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDigital control panel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMulti-language interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlarm history log.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHour meter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClogged filter alarm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional H13 and H14 filtration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional activated carbon filtration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic Start\/Stop capability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with multiple extraction arm configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eUNI 2H\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFan Capacity\u003c\/td\u003e\n\u003ctd\u003e1,471 CFM (2,500 m³\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtraction Capacity\u003c\/td\u003e\n\u003ctd\u003e647 CFM (1,100 m³\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiltration Efficiency\u003c\/td\u003e\n\u003ctd\u003eE12 \u0026gt;99.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Area\u003c\/td\u003e\n\u003ctd\u003e156 sq. ft. (14.5 m²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Power\u003c\/td\u003e\n\u003ctd\u003e1.5 HP (1.1 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230V \/ 1 Phase \/ 50Hz or 400V \/ 3 Phase \/ 50–60Hz*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Level\u003c\/td\u003e\n\u003ctd\u003e73 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e23.6 x 31.5 x 47.2 in. (600 x 800 x 1200 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e231 lbs. (105 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e*Verify final electrical configuration for North American installations before publication. Catalog specifications include both single-phase and three-phase versions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eImportant Operating Considerations\u003c\/h2\u003e\n\u003cp\u003eThe UNI 2H is designed for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDry welding fumes only.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRegular daily welding operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial fabrication environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe unit is \u003cstrong\u003enot suitable for oily fumes\u003c\/strong\u003e and is \u003cstrong\u003enot approved for use in potentially explosive or hazardous atmospheres\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eBuilt for Professional Industrial Welding Fume Control\u003c\/h2\u003e\n\u003cp\u003eThe AerService UNI 2H delivers professional-grade welding fume extraction for facilities requiring larger filtration capacity, advanced system monitoring, and flexible filtration configurations. Combining high-efficiency E12 filtration, digital controls, optional HEPA upgrades, and industrial-duty construction, the UNI 2H provides a versatile solution for fabrication facilities seeking dependable daily welding fume control with room to grow into more demanding applications.\u003c\/p\u003e","brand":"AerService (Made in Italy)","offers":[{"title":"Default Title","offer_id":62805870477471,"sku":null,"price":3195.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0100\/8271\/3696\/files\/uni-2h-professional-mobile-welding-fume-extraction-system-welding-fume-extraction-systems-quantum-machinery-group-usa-2609431.jpg?v=1780488066"},{"product_id":"uni-3-2-w3-self-cleaning-mobile-filter-unit-for-welding-fumes-single-arm","title":"UNI 3.2.1 W3: Self-Cleaning Mobile Filter Unit for Welding Fumes (Single Arm)","description":"\u003ch1 data-section-id=\"5kl2v5\" data-start=\"0\" data-end=\"66\"\u003eUNI 3.2.1 W3: Self-Cleaning Mobile Filter Unit for Welding Fumes\u003c\/h1\u003e\n\u003ch2 data-section-id=\"1pe2nn9\" data-start=\"68\" data-end=\"146\"\u003eSelf-Cleaning Welding Fume Extraction for Intensive Production Applications\u003c\/h2\u003e\n\u003cp data-start=\"148\" data-end=\"655\"\u003eThe \u003cstrong data-start=\"152\" data-end=\"179\"\u003eAerService UNI 3.2.1 W3\u003c\/strong\u003e is a self-cleaning mobile welding fume extraction system engineered for demanding fabrication environments requiring continuous operation, high airflow performance, and minimal maintenance downtime. Designed for intensive daily use, the UNI 3.2.1 W3 combines W3-certified filtration, automatic compressed-air filter cleaning, and professional source-capture extraction in a robust mobile platform built for production welding operations.\u003c\/p\u003e\n\u003cp data-start=\"657\" data-end=\"1037\"\u003eFeaturing a high-capacity dual-cartridge filtration system, integrated pre-separation chamber, automatic filter cleaning technology, and advanced digital controls, the UNI 3.2.1 W3 delivers reliable extraction performance for facilities where welding fumes, grinding dust, and thermal cutting particulate are generated throughout the workday.\u003c\/p\u003e\n\u003chr data-start=\"1039\" data-end=\"1042\"\u003e\n\u003ch2 data-section-id=\"xyzixz\" data-start=\"1044\" data-end=\"1083\"\u003eWhy Self-Cleaning Filtration Matters\u003c\/h2\u003e\n\u003cp data-start=\"1085\" data-end=\"1315\"\u003eIn high-production welding environments, filter loading can reduce airflow performance and increase maintenance requirements. Traditional manual-cleaning systems often require production interruptions to restore filter efficiency.\u003c\/p\u003e\n\u003cp data-start=\"1317\" data-end=\"1509\"\u003eThe UNI 3.2.1 W3 addresses these challenges through an automatic compressed-air cleaning system that continuously maintains filter performance while reducing operator intervention. This helps:\u003c\/p\u003e\n\u003cul data-start=\"1511\" data-end=\"1730\"\u003e\n\u003cli data-section-id=\"cl4cy7\" data-start=\"1511\" data-end=\"1553\"\u003eMaintain consistent airflow performance.\u003c\/li\u003e\n\u003cli data-section-id=\"bheri3\" data-start=\"1554\" data-end=\"1583\"\u003eExtend filter service life.\u003c\/li\u003e\n\u003cli data-section-id=\"1hpiuak\" data-start=\"1584\" data-end=\"1614\"\u003eReduce maintenance downtime.\u003c\/li\u003e\n\u003cli data-section-id=\"1nakutd\" data-start=\"1615\" data-end=\"1651\"\u003eImprove overall system efficiency.\u003c\/li\u003e\n\u003cli data-section-id=\"1ad05c1\" data-start=\"1652\" data-end=\"1695\"\u003eSupport continuous production operations.\u003c\/li\u003e\n\u003cli data-section-id=\"1sqlmh5\" data-start=\"1696\" data-end=\"1730\"\u003eLower long-term operating costs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1732\" data-end=\"1960\"\u003eBy automatically cleaning the filter cartridges during operation, the UNI 3.2.1 W3 is designed to keep fabrication environments running efficiently throughout demanding production schedules.\u003c\/p\u003e\n\u003chr data-start=\"1962\" data-end=\"1965\"\u003e\n\u003ch2 data-section-id=\"anecoi\" data-start=\"1967\" data-end=\"2016\"\u003eDesigned for Intensive Industrial Applications\u003c\/h2\u003e\n\u003cp data-start=\"2018\" data-end=\"2138\"\u003eThe UNI 3.2.1 W3 is built for facilities where welding and fabrication activities occur continuously throughout the day.\u003c\/p\u003e\n\u003cp data-start=\"2140\" data-end=\"2167\"\u003eIdeal applications include:\u003c\/p\u003e\n\u003cul data-start=\"2169\" data-end=\"2467\"\u003e\n\u003cli data-section-id=\"18r8vgy\" data-start=\"2169\" data-end=\"2195\"\u003eHeavy fabrication shops.\u003c\/li\u003e\n\u003cli data-section-id=\"6zw4md\" data-start=\"2196\" data-end=\"2223\"\u003eManufacturing facilities.\u003c\/li\u003e\n\u003cli data-section-id=\"oq8yl5\" data-start=\"2224\" data-end=\"2256\"\u003eProduction welding operations.\u003c\/li\u003e\n\u003cli data-section-id=\"1igkd2o\" data-start=\"2257\" data-end=\"2288\"\u003eStructural steel fabrication.\u003c\/li\u003e\n\u003cli data-section-id=\"16sgvdd\" data-start=\"2289\" data-end=\"2315\"\u003eIndustrial metalworking.\u003c\/li\u003e\n\u003cli data-section-id=\"1jyhe3v\" data-start=\"2316\" data-end=\"2352\"\u003eMaintenance and repair operations.\u003c\/li\u003e\n\u003cli data-section-id=\"j81ofn\" data-start=\"2353\" data-end=\"2405\"\u003eFabrication cells requiring continuous extraction.\u003c\/li\u003e\n\u003cli data-section-id=\"1h21jhf\" data-start=\"2406\" data-end=\"2467\"\u003eFacilities generating both welding fumes and grinding dust.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2469\" data-end=\"2663\"\u003eUnlike entry-level mobile extractors, the UNI 3.2.1 W3 is specifically engineered for intensive-duty applications where reliability and uptime are critical.\u003c\/p\u003e\n\u003chr data-start=\"2665\" data-end=\"2668\"\u003e\n\u003ch2 data-section-id=\"bafxwr\" data-start=\"2670\" data-end=\"2708\"\u003eW3-Certified Filtration Performance\u003c\/h2\u003e\n\u003cp data-start=\"2710\" data-end=\"2925\"\u003eThe UNI 3.2.1 W3 is certified to \u003cstrong data-start=\"2743\" data-end=\"2770\"\u003eW3 filtration standards\u003c\/strong\u003e with filtration efficiency exceeding \u003cstrong data-start=\"2808\" data-end=\"2815\"\u003e99%\u003c\/strong\u003e, making it suitable for demanding welding fume extraction applications.\u003c\/p\u003e\n\u003cp data-start=\"2927\" data-end=\"2958\"\u003eThe filtration system utilizes:\u003c\/p\u003e\n\u003ch3 data-section-id=\"10qh9cm\" data-start=\"2960\" data-end=\"2986\"\u003ePre-Separation Chamber\u003c\/h3\u003e\n\u003cp data-start=\"2988\" data-end=\"3236\"\u003eIncoming air enters a dedicated pre-chamber designed to separate heavier dust and sparks before they reach the primary filtration cartridges. This reduces filter loading and improves overall system performance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"jw147v\" data-start=\"3238\" data-end=\"3267\"\u003eDual Cartridge Filtration\u003c\/h3\u003e\n\u003cp data-start=\"3269\" data-end=\"3481\"\u003eThe system incorporates two high-capacity cartridge filters utilizing \u003cstrong data-start=\"3339\" data-end=\"3371\"\u003eSintexx Plus nanofiber media\u003c\/strong\u003e, providing exceptional filtration efficiency and extended service life.\u003c\/p\u003e\n\u003ch3 data-section-id=\"de96ni\" data-start=\"3483\" data-end=\"3520\"\u003eAutomatic Compressed-Air Cleaning\u003c\/h3\u003e\n\u003cp data-start=\"3522\" data-end=\"3753\"\u003eThe integrated reverse-pulse cleaning system automatically removes accumulated particulate from the filter surface, maintaining airflow performance without requiring manual cleaning procedures.\u003c\/p\u003e\n\u003chr data-start=\"3755\" data-end=\"3758\"\u003e\n\u003ch2 data-section-id=\"1sq4lf\" data-start=\"3760\" data-end=\"3794\"\u003eAdvanced Digital Control System\u003c\/h2\u003e\n\u003cp data-start=\"3796\" data-end=\"3917\"\u003eThe UNI 3.2.1 W3 features a digital control panel designed to simplify operation and provide real-time system monitoring.\u003c\/p\u003e\n\u003cp data-start=\"3919\" data-end=\"3936\"\u003eFeatures include:\u003c\/p\u003e\n\u003cul data-start=\"3938\" data-end=\"4119\"\u003e\n\u003cli data-section-id=\"1n0491x\" data-start=\"3938\" data-end=\"3965\"\u003eMulti-language interface.\u003c\/li\u003e\n\u003cli data-section-id=\"1q8rizx\" data-start=\"3966\" data-end=\"3979\"\u003eHour meter.\u003c\/li\u003e\n\u003cli data-section-id=\"1erkvn7\" data-start=\"3980\" data-end=\"4000\"\u003eAlarm history log.\u003c\/li\u003e\n\u003cli data-section-id=\"hybv4u\" data-start=\"4001\" data-end=\"4028\"\u003eFilter status monitoring.\u003c\/li\u003e\n\u003cli data-section-id=\"e5yl6c\" data-start=\"4029\" data-end=\"4052\"\u003eClogged filter alarm.\u003c\/li\u003e\n\u003cli data-section-id=\"ymte4a\" data-start=\"4053\" data-end=\"4081\"\u003eCompressed-air monitoring.\u003c\/li\u003e\n\u003cli data-section-id=\"1g9zqyv\" data-start=\"4082\" data-end=\"4119\"\u003eAutomatic Start\/Stop functionality.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4121\" data-end=\"4259\"\u003eThese features help operators maximize performance while reducing maintenance-related interruptions.\u003c\/p\u003e\n\u003chr data-start=\"4261\" data-end=\"4264\"\u003e\n\u003ch2 data-section-id=\"zwvhs2\" data-start=\"4266\" data-end=\"4293\"\u003eOptimized Airflow Design\u003c\/h2\u003e\n\u003cp data-start=\"4295\" data-end=\"4396\"\u003eThe UNI 3.2.1 W3 incorporates several airflow management features to maximize extraction performance.\u003c\/p\u003e\n\u003cp data-start=\"4398\" data-end=\"4412\"\u003eThese include:\u003c\/p\u003e\n\u003cul data-start=\"4414\" data-end=\"4588\"\u003e\n\u003cli data-section-id=\"k8poj3\" data-start=\"4414\" data-end=\"4447\"\u003ePlug-fan extraction technology.\u003c\/li\u003e\n\u003cli data-section-id=\"1uy3rpt\" data-start=\"4448\" data-end=\"4479\"\u003eIntegrated airflow equalizer.\u003c\/li\u003e\n\u003cli data-section-id=\"1noxf3l\" data-start=\"4480\" data-end=\"4514\"\u003eHigh-capacity extraction system.\u003c\/li\u003e\n\u003cli data-section-id=\"hyq78z\" data-start=\"4515\" data-end=\"4544\"\u003eDual-stage dust collection.\u003c\/li\u003e\n\u003cli data-section-id=\"69a9xp\" data-start=\"4545\" data-end=\"4588\"\u003eOptimized discharge airflow distribution.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4590\" data-end=\"4741\"\u003eThe result is a system engineered to maintain stable extraction performance under demanding operating conditions.\u003c\/p\u003e\n\u003chr data-start=\"4743\" data-end=\"4746\"\u003e\n\u003ch2 data-section-id=\"1heyptf\" data-start=\"4748\" data-end=\"4792\"\u003eFlexible Filtration and Accessory Options\u003c\/h2\u003e\n\u003cp data-start=\"4794\" data-end=\"4878\"\u003eThe UNI 3.2.1 W3 can be configured to meet a wide range of application requirements.\u003c\/p\u003e\n\u003cp data-start=\"4880\" data-end=\"4906\"\u003eAvailable options include:\u003c\/p\u003e\n\u003cul data-start=\"4908\" data-end=\"5126\"\u003e\n\u003cli data-section-id=\"1wf8rsk\" data-start=\"4908\" data-end=\"4952\"\u003e6 in. (160 mm) articulated extraction arm.\u003c\/li\u003e\n\u003cli data-section-id=\"nqlam\" data-start=\"4953\" data-end=\"4985\"\u003eHood-mounted LED lighting kit.\u003c\/li\u003e\n\u003cli data-section-id=\"1748x7e\" data-start=\"4986\" data-end=\"5021\"\u003eAdditional spark arrestor filter.\u003c\/li\u003e\n\u003cli data-section-id=\"1q2880g\" data-start=\"5022\" data-end=\"5052\"\u003eActivated carbon filtration.\u003c\/li\u003e\n\u003cli data-section-id=\"1y08s8f\" data-start=\"5053\" data-end=\"5075\"\u003eH14 HEPA filtration.\u003c\/li\u003e\n\u003cli data-section-id=\"1k7o87x\" data-start=\"5076\" data-end=\"5126\"\u003eDischarge kit for external exhaust applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5128\" data-end=\"5278\"\u003eThis flexibility allows the system to be tailored to specific fabrication processes and facility requirements.\u003c\/p\u003e\n\u003chr data-start=\"5280\" data-end=\"5283\"\u003e\n\u003ch2 data-section-id=\"x43ryu\" data-start=\"5285\" data-end=\"5307\"\u003eSupported Processes\u003c\/h2\u003e\n\u003cp data-start=\"5309\" data-end=\"5342\"\u003eThe UNI 3.2.1 W3 is suitable for:\u003c\/p\u003e\n\u003cul data-start=\"5344\" data-end=\"5478\"\u003e\n\u003cli data-section-id=\"1l448pd\" data-start=\"5344\" data-end=\"5357\"\u003eMIG Welding\u003c\/li\u003e\n\u003cli data-section-id=\"1cggtnd\" data-start=\"5358\" data-end=\"5371\"\u003eMAG Welding\u003c\/li\u003e\n\u003cli data-section-id=\"116658u\" data-start=\"5372\" data-end=\"5396\"\u003ePulsed MIG\/MAG Welding\u003c\/li\u003e\n\u003cli data-section-id=\"qyiua0\" data-start=\"5397\" data-end=\"5410\"\u003eTIG Welding\u003c\/li\u003e\n\u003cli data-section-id=\"v9v5qy\" data-start=\"5411\" data-end=\"5432\"\u003eMMA \/ Stick Welding\u003c\/li\u003e\n\u003cli data-section-id=\"3717ra\" data-start=\"5433\" data-end=\"5456\"\u003eManual Plasma Cutting\u003c\/li\u003e\n\u003cli data-section-id=\"12uhkrc\" data-start=\"5457\" data-end=\"5478\"\u003eGrinding Operations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5480\" data-end=\"5608\"\u003eThe unit is designed for dry welding fumes and particulate generated by these processes.\u003c\/p\u003e\n\u003chr data-start=\"5610\" data-end=\"5613\"\u003e\n\u003ch2 data-section-id=\"19vd27d\" data-start=\"5615\" data-end=\"5636\"\u003eIdeal Applications\u003c\/h2\u003e\n\u003cp data-start=\"5638\" data-end=\"5684\"\u003eThe UNI 3.2.1 W3 is an excellent solution for:\u003c\/p\u003e\n\u003cul data-start=\"5686\" data-end=\"5934\"\u003e\n\u003cli data-section-id=\"1l5s5d2\" data-start=\"5686\" data-end=\"5722\"\u003eProduction fabrication facilities.\u003c\/li\u003e\n\u003cli data-section-id=\"gp6cj\" data-start=\"5723\" data-end=\"5756\"\u003eHeavy manufacturing operations.\u003c\/li\u003e\n\u003cli data-section-id=\"1igkd2o\" data-start=\"5757\" data-end=\"5788\"\u003eStructural steel fabrication.\u003c\/li\u003e\n\u003cli data-section-id=\"k389bd\" data-start=\"5789\" data-end=\"5805\"\u003eWelding cells.\u003c\/li\u003e\n\u003cli data-section-id=\"oakoex\" data-start=\"5806\" data-end=\"5826\"\u003eGrinding stations.\u003c\/li\u003e\n\u003cli data-section-id=\"5rh3ei\" data-start=\"5827\" data-end=\"5857\"\u003ePlasma cutting workstations.\u003c\/li\u003e\n\u003cli data-section-id=\"1jdu3hb\" data-start=\"5858\" data-end=\"5894\"\u003eIndustrial maintenance facilities.\u003c\/li\u003e\n\u003cli data-section-id=\"rpdr3a\" data-start=\"5895\" data-end=\"5934\"\u003eContinuous-duty welding environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5936\" data-end=\"5939\"\u003e\n\u003ch2 data-section-id=\"46cx1w\" data-start=\"5941\" data-end=\"5972\"\u003eWho Is the UNI 3.2.1 W3 For?\u003c\/h2\u003e\n\u003cp data-start=\"5974\" data-end=\"6023\"\u003eThe UNI 3.2.1 W3 is ideal for organizations that:\u003c\/p\u003e\n\u003cul data-start=\"6025\" data-end=\"6349\"\u003e\n\u003cli data-section-id=\"np9t44\" data-start=\"6025\" data-end=\"6079\"\u003ePerform welding continuously throughout the workday.\u003c\/li\u003e\n\u003cli data-section-id=\"15v8moj\" data-start=\"6080\" data-end=\"6116\"\u003eRequire automatic filter cleaning.\u003c\/li\u003e\n\u003cli data-section-id=\"1pq0yea\" data-start=\"6117\" data-end=\"6160\"\u003eNeed W3-certified filtration performance.\u003c\/li\u003e\n\u003cli data-section-id=\"r42roa\" data-start=\"6161\" data-end=\"6205\"\u003eGenerate significant welding fume volumes.\u003c\/li\u003e\n\u003cli data-section-id=\"1dxq9so\" data-start=\"6206\" data-end=\"6255\"\u003ePerform grinding and plasma cutting operations.\u003c\/li\u003e\n\u003cli data-section-id=\"kipjjn\" data-start=\"6256\" data-end=\"6296\"\u003eWant to minimize maintenance downtime.\u003c\/li\u003e\n\u003cli data-section-id=\"1dp43nw\" data-start=\"6297\" data-end=\"6349\"\u003eRequire industrial-duty source-capture extraction.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6351\" data-end=\"6354\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"6356\" data-end=\"6371\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"6373\" data-end=\"6939\"\u003e\n\u003cli data-section-id=\"1jopxsz\" data-start=\"6373\" data-end=\"6427\"\u003eW3-certified filtration efficiency greater than 99%.\u003c\/li\u003e\n\u003cli data-section-id=\"o37626\" data-start=\"6428\" data-end=\"6471\"\u003eAutomatic compressed-air filter cleaning.\u003c\/li\u003e\n\u003cli data-section-id=\"iz4sdv\" data-start=\"6472\" data-end=\"6507\"\u003eDual-cartridge filtration system.\u003c\/li\u003e\n\u003cli data-section-id=\"1d29ih\" data-start=\"6508\" data-end=\"6546\"\u003eSintexx Plus nanofiber filter media.\u003c\/li\u003e\n\u003cli data-section-id=\"1cee0xx\" data-start=\"6547\" data-end=\"6599\"\u003ePre-separation chamber for dust and spark removal.\u003c\/li\u003e\n\u003cli data-section-id=\"k8poj3\" data-start=\"6600\" data-end=\"6633\"\u003ePlug-fan extraction technology.\u003c\/li\u003e\n\u003cli data-section-id=\"q62kt\" data-start=\"6634\" data-end=\"6658\"\u003eDigital control panel.\u003c\/li\u003e\n\u003cli data-section-id=\"1g9zqyv\" data-start=\"6659\" data-end=\"6696\"\u003eAutomatic Start\/Stop functionality.\u003c\/li\u003e\n\u003cli data-section-id=\"ymte4a\" data-start=\"6697\" data-end=\"6725\"\u003eCompressed-air monitoring.\u003c\/li\u003e\n\u003cli data-section-id=\"1erkvn7\" data-start=\"6726\" data-end=\"6746\"\u003eAlarm history log.\u003c\/li\u003e\n\u003cli data-section-id=\"e5yl6c\" data-start=\"6747\" data-end=\"6770\"\u003eClogged filter alarm.\u003c\/li\u003e\n\u003cli data-section-id=\"1eszi9q\" data-start=\"6771\" data-end=\"6802\"\u003eDual dust collection drawers.\u003c\/li\u003e\n\u003cli data-section-id=\"ex94wy\" data-start=\"6803\" data-end=\"6835\"\u003eMobile industrial-duty design.\u003c\/li\u003e\n\u003cli data-section-id=\"rpfkw1\" data-start=\"6836\" data-end=\"6939\"\u003eCompatible with optional H14 and activated carbon filtration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6941\" data-end=\"6944\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"6946\" data-end=\"6973\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"6975\" data-end=\"7512\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"6975\" data-end=\"7007\"\u003e\n\u003ctr data-start=\"6975\" data-end=\"7007\"\u003e\n\u003cth data-start=\"6975\" data-end=\"6991\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"6991\" data-end=\"7007\" data-col-size=\"md\" class=\"last:pe-10\"\u003eUNI 3.2.1 W3\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"7040\" data-end=\"7512\"\u003e\n\u003ctr data-start=\"7040\" data-end=\"7081\"\u003e\n\u003ctd data-start=\"7040\" data-end=\"7055\" data-col-size=\"sm\"\u003eFan Capacity\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7055\" data-end=\"7081\"\u003e1,483 CFM (2,520 m³\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7082\" data-end=\"7128\"\u003e\n\u003ctd data-start=\"7082\" data-end=\"7104\" data-col-size=\"sm\"\u003eExtraction Capacity\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7104\" data-end=\"7128\"\u003e824 CFM (1,400 m³\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7129\" data-end=\"7174\"\u003e\n\u003ctd data-start=\"7129\" data-end=\"7153\" data-col-size=\"sm\"\u003eFiltration Efficiency\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7153\" data-end=\"7174\"\u003eW3 Certified \u0026gt;99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7175\" data-end=\"7212\"\u003e\n\u003ctd data-start=\"7175\" data-end=\"7189\" data-col-size=\"sm\"\u003eFilter Area\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7189\" data-end=\"7212\"\u003e172 sq. ft. (16 m²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7213\" data-end=\"7254\"\u003e\n\u003ctd data-start=\"7213\" data-end=\"7228\" data-col-size=\"sm\"\u003eFilter Media\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7228\" data-end=\"7254\"\u003eSintexx Plus Nanofiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7255\" data-end=\"7286\"\u003e\n\u003ctd data-start=\"7255\" data-end=\"7269\" data-col-size=\"sm\"\u003eMotor Power\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7269\" data-end=\"7286\"\u003e2 HP (1.5 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7287\" data-end=\"7351\"\u003e\n\u003ctd data-start=\"7287\" data-end=\"7297\" data-col-size=\"sm\"\u003eVoltage\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7297\" data-end=\"7351\"\u003e230V \/ 1 Phase \/ 50Hz or 400V \/ 3 Phase \/ 50-60Hz*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7352\" data-end=\"7378\"\u003e\n\u003ctd data-start=\"7352\" data-end=\"7366\" data-col-size=\"sm\"\u003eNoise Level\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7366\" data-end=\"7378\"\u003e75 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7379\" data-end=\"7418\"\u003e\n\u003ctd data-start=\"7379\" data-end=\"7407\" data-col-size=\"sm\"\u003eCompressed Air Connection\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7407\" data-end=\"7418\"\u003e1\/2 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7419\" data-end=\"7481\"\u003e\n\u003ctd data-start=\"7419\" data-end=\"7432\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-start=\"7432\" data-end=\"7481\" data-col-size=\"md\"\u003e29.1 x 46.5 x 43.7 in. (740 x 1180 x 1110 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7482\" data-end=\"7512\"\u003e\n\u003ctd data-start=\"7482\" data-end=\"7491\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7491\" data-end=\"7512\"\u003e401 lbs. (182 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"7514\" data-end=\"7646\"\u003e*Verify final electrical configuration for North American installations before publication.\u003c\/p\u003e\n\u003chr data-start=\"7648\" data-end=\"7651\"\u003e\n\u003ch2 data-section-id=\"1xfdujf\" data-start=\"7653\" data-end=\"7690\"\u003eImportant Operating Considerations\u003c\/h2\u003e\n\u003cp data-start=\"7692\" data-end=\"7725\"\u003eThe UNI 3.2.1 W3 is designed for:\u003c\/p\u003e\n\u003cul data-start=\"7727\" data-end=\"7838\"\u003e\n\u003cli data-section-id=\"mola8r\" data-start=\"7727\" data-end=\"7747\"\u003eDry welding fumes.\u003c\/li\u003e\n\u003cli data-section-id=\"1o2i76u\" data-start=\"7748\" data-end=\"7764\"\u003eGrinding dust.\u003c\/li\u003e\n\u003cli data-section-id=\"lk6x8c\" data-start=\"7765\" data-end=\"7801\"\u003eManual plasma cutting particulate.\u003c\/li\u003e\n\u003cli data-section-id=\"io4itu\" data-start=\"7802\" data-end=\"7838\"\u003eIntensive production environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"7840\" data-end=\"8087\"\u003eThe unit is \u003cstrong data-start=\"7852\" data-end=\"7883\"\u003enot suitable for oily fumes\u003c\/strong\u003e and is \u003cstrong data-start=\"7891\" data-end=\"7965\"\u003enot approved for use in potentially explosive or hazardous atmospheres\u003c\/strong\u003e. Operation of the automatic cleaning system requires a compressed-air connection.\u003c\/p\u003e\n\u003chr data-start=\"8089\" data-end=\"8092\"\u003e\n\u003ch2 data-section-id=\"vhkqj8\" data-start=\"8094\" data-end=\"8149\"\u003eBuilt for Continuous Industrial Welding Fume Control\u003c\/h2\u003e\n\u003cp data-start=\"8151\" data-end=\"8624\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe AerService UNI 3.2.1 W3 delivers industrial-grade welding fume extraction for facilities where productivity, filtration performance, and uptime are critical. Combining automatic filter cleaning, W3-certified filtration, advanced airflow management, and professional digital controls, the UNI 3.2.1 W3 provides a powerful source-capture solution for demanding fabrication environments requiring reliable continuous-duty operation.\u003c\/p\u003e","brand":"AerService (Made in Italy)","offers":[{"title":"Default Title","offer_id":62805870837919,"sku":null,"price":5795.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0100\/8271\/3696\/files\/uni-321-w3-self-cleaning-mobile-filter-unit-for-welding-fumes-single-arm-welding-fume-extraction-systems-quantum-machinery-group-usa-2381247.jpg?v=1780488066"},{"product_id":"uni-3-2-2-w3-dual-arm-self-cleaning-mobile-filter-unit-for-welding-fumes","title":"UNI 3.2.2 W3: Dual-Arm Self-Cleaning Mobile Filter Unit for Welding Fumes","description":"\u003ch1 data-section-id=\"wklffm\" data-start=\"0\" data-end=\"66\"\u003eUNI 3.2.2 W3: Self-Cleaning Mobile Filter Unit for Welding Fumes\u003c\/h1\u003e\n\u003ch2 data-section-id=\"wpew51\" data-start=\"68\" data-end=\"150\"\u003eSelf-Cleaning Welding Fume Extraction for Multi-Station Production Environments\u003c\/h2\u003e\n\u003cp data-start=\"152\" data-end=\"639\"\u003eThe \u003cstrong data-start=\"156\" data-end=\"183\"\u003eAerService UNI 3.2.2 W3\u003c\/strong\u003e is a self-cleaning mobile welding fume extraction system designed for fabrication facilities requiring source-capture extraction at two welding stations simultaneously. Engineered for intensive industrial applications, the UNI 3.2.2 W3 combines W3-certified filtration, automatic compressed-air filter cleaning, and dual-arm extraction capability to deliver reliable fume control in demanding production environments.\u003c\/p\u003e\n\u003cp data-start=\"641\" data-end=\"1074\"\u003eBuilt around the same industrial platform as the UNI 3.2.1 W3, the dual-arm UNI 3.2.2 W3 increases workstation flexibility by allowing extraction from two separate welding positions while maintaining high-efficiency filtration and continuous-duty operation. This makes it an ideal solution for fabrication shops seeking to maximize extraction coverage without adding additional filtration units.\u003c\/p\u003e\n\u003chr data-start=\"1076\" data-end=\"1079\"\u003e\n\u003ch2 data-section-id=\"nalhiu\" data-start=\"1081\" data-end=\"1108\"\u003eWhy Dual-Arm Extraction?\u003c\/h2\u003e\n\u003cp data-start=\"1110\" data-end=\"1348\"\u003eMany fabrication facilities operate multiple welding stations within the same work area. Installing a dedicated extraction system for every station can increase costs, consume valuable floor space, and complicate maintenance requirements.\u003c\/p\u003e\n\u003cp data-start=\"1350\" data-end=\"1478\"\u003eThe UNI 3.2.2 W3 provides a centralized mobile solution capable of supporting two extraction arms from a single filtration unit.\u003c\/p\u003e\n\u003cp data-start=\"1480\" data-end=\"1497\"\u003eBenefits include:\u003c\/p\u003e\n\u003cul data-start=\"1499\" data-end=\"1756\"\u003e\n\u003cli data-section-id=\"3v7dt9\" data-start=\"1499\" data-end=\"1539\"\u003eCoverage for two welding workstations.\u003c\/li\u003e\n\u003cli data-section-id=\"3jbdk\" data-start=\"1540\" data-end=\"1573\"\u003eImproved equipment utilization.\u003c\/li\u003e\n\u003cli data-section-id=\"13m2zma\" data-start=\"1574\" data-end=\"1609\"\u003eReduced floor space requirements.\u003c\/li\u003e\n\u003cli data-section-id=\"rqnql9\" data-start=\"1610\" data-end=\"1663\"\u003eLower maintenance costs compared to multiple units.\u003c\/li\u003e\n\u003cli data-section-id=\"1ddq8sx\" data-start=\"1664\" data-end=\"1699\"\u003eFlexible workstation positioning.\u003c\/li\u003e\n\u003cli data-section-id=\"vrqkcz\" data-start=\"1700\" data-end=\"1756\"\u003eIncreased productivity in multi-operator environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1758\" data-end=\"1903\"\u003eThe dual-arm design helps facilities maximize extraction coverage while maintaining operational efficiency.\u003c\/p\u003e\n\u003chr data-start=\"1905\" data-end=\"1908\"\u003e\n\u003ch2 data-section-id=\"anecoi\" data-start=\"1910\" data-end=\"1959\"\u003eDesigned for Intensive Industrial Applications\u003c\/h2\u003e\n\u003cp data-start=\"1961\" data-end=\"2110\"\u003eThe UNI 3.2.2 W3 is built for fabrication environments where welding, grinding, and thermal cutting activities occur continuously throughout the day.\u003c\/p\u003e\n\u003cp data-start=\"2112\" data-end=\"2139\"\u003eIdeal applications include:\u003c\/p\u003e\n\u003cul data-start=\"2141\" data-end=\"2414\"\u003e\n\u003cli data-section-id=\"1nk1y2u\" data-start=\"2141\" data-end=\"2172\"\u003eHeavy fabrication facilities.\u003c\/li\u003e\n\u003cli data-section-id=\"1igkd2o\" data-start=\"2173\" data-end=\"2204\"\u003eStructural steel fabrication.\u003c\/li\u003e\n\u003cli data-section-id=\"1vmyto2\" data-start=\"2205\" data-end=\"2228\"\u003eManufacturing plants.\u003c\/li\u003e\n\u003cli data-section-id=\"oq8yl5\" data-start=\"2229\" data-end=\"2261\"\u003eProduction welding operations.\u003c\/li\u003e\n\u003cli data-section-id=\"1bdk7kn\" data-start=\"2262\" data-end=\"2292\"\u003eMulti-station welding cells.\u003c\/li\u003e\n\u003cli data-section-id=\"dc9udn\" data-start=\"2293\" data-end=\"2330\"\u003eIndustrial maintenance departments.\u003c\/li\u003e\n\u003cli data-section-id=\"wek2ao\" data-start=\"2331\" data-end=\"2357\"\u003eMetal fabrication shops.\u003c\/li\u003e\n\u003cli data-section-id=\"1fioyoi\" data-start=\"2358\" data-end=\"2414\"\u003eFacilities generating welding fumes and grinding dust.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2416\" data-end=\"2591\"\u003eIts dual-arm configuration makes it particularly effective in environments where multiple operators require simultaneous fume extraction.\u003c\/p\u003e\n\u003chr data-start=\"2593\" data-end=\"2596\"\u003e\n\u003ch2 data-section-id=\"bafxwr\" data-start=\"2598\" data-end=\"2636\"\u003eW3-Certified Filtration Performance\u003c\/h2\u003e\n\u003cp data-start=\"2638\" data-end=\"2862\"\u003eThe UNI 3.2.2 W3 is certified to \u003cstrong data-start=\"2671\" data-end=\"2698\"\u003eW3 filtration standards\u003c\/strong\u003e with filtration efficiency exceeding \u003cstrong data-start=\"2736\" data-end=\"2743\"\u003e99%\u003c\/strong\u003e, providing high-performance welding fume filtration for industrial applications.\u003c\/p\u003e\n\u003cp data-start=\"2864\" data-end=\"2895\"\u003eThe filtration system includes:\u003c\/p\u003e\n\u003ch3 data-section-id=\"10qh9cm\" data-start=\"2897\" data-end=\"2923\"\u003ePre-Separation Chamber\u003c\/h3\u003e\n\u003cp data-start=\"2925\" data-end=\"3144\"\u003eA dedicated pre-separation chamber captures heavier dust and sparks before they reach the primary filtration cartridges, helping extend filter life and maintain airflow performance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"jw147v\" data-start=\"3146\" data-end=\"3175\"\u003eDual Cartridge Filtration\u003c\/h3\u003e\n\u003cp data-start=\"3177\" data-end=\"3388\"\u003eTwo high-capacity cartridge filters utilizing \u003cstrong data-start=\"3223\" data-end=\"3255\"\u003eSintexx Plus nanofiber media\u003c\/strong\u003e provide exceptional particulate capture efficiency while supporting continuous-duty operation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"de96ni\" data-start=\"3390\" data-end=\"3427\"\u003eAutomatic Compressed-Air Cleaning\u003c\/h3\u003e\n\u003cp data-start=\"3429\" data-end=\"3657\"\u003eThe integrated reverse-pulse cleaning system automatically removes accumulated particulate from the filter surface, reducing maintenance requirements and helping maintain consistent airflow.\u003c\/p\u003e\n\u003chr data-start=\"3659\" data-end=\"3662\"\u003e\n\u003ch2 data-section-id=\"1sq4lf\" data-start=\"3664\" data-end=\"3698\"\u003eAdvanced Digital Control System\u003c\/h2\u003e\n\u003cp data-start=\"3700\" data-end=\"3812\"\u003eThe UNI 3.2.2 W3 features a digital control panel designed to simplify operation and monitor system performance.\u003c\/p\u003e\n\u003cp data-start=\"3814\" data-end=\"3831\"\u003eFeatures include:\u003c\/p\u003e\n\u003cul data-start=\"3833\" data-end=\"4007\"\u003e\n\u003cli data-section-id=\"1n0491x\" data-start=\"3833\" data-end=\"3860\"\u003eMulti-language interface.\u003c\/li\u003e\n\u003cli data-section-id=\"1q8rizx\" data-start=\"3861\" data-end=\"3874\"\u003eHour meter.\u003c\/li\u003e\n\u003cli data-section-id=\"1erkvn7\" data-start=\"3875\" data-end=\"3895\"\u003eAlarm history log.\u003c\/li\u003e\n\u003cli data-section-id=\"u2ddfu\" data-start=\"3896\" data-end=\"3916\"\u003eFilter monitoring.\u003c\/li\u003e\n\u003cli data-section-id=\"e5yl6c\" data-start=\"3917\" data-end=\"3940\"\u003eClogged filter alarm.\u003c\/li\u003e\n\u003cli data-section-id=\"ymte4a\" data-start=\"3941\" data-end=\"3969\"\u003eCompressed-air monitoring.\u003c\/li\u003e\n\u003cli data-section-id=\"1g9zqyv\" data-start=\"3970\" data-end=\"4007\"\u003eAutomatic Start\/Stop functionality.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4009\" data-end=\"4154\"\u003eThese capabilities help operators maintain peak extraction performance while minimizing unplanned downtime.\u003c\/p\u003e\n\u003chr data-start=\"4156\" data-end=\"4159\"\u003e\n\u003ch2 data-section-id=\"p78do1\" data-start=\"4161\" data-end=\"4204\"\u003eOptimized Airflow for Dual-Arm Operation\u003c\/h2\u003e\n\u003cp data-start=\"4206\" data-end=\"4336\"\u003eThe UNI 3.2.2 W3 is specifically configured to support two extraction arms while maintaining effective source-capture performance.\u003c\/p\u003e\n\u003cp data-start=\"4338\" data-end=\"4355\"\u003eFeatures include:\u003c\/p\u003e\n\u003cul data-start=\"4357\" data-end=\"4525\"\u003e\n\u003cli data-section-id=\"k8poj3\" data-start=\"4357\" data-end=\"4390\"\u003ePlug-fan extraction technology.\u003c\/li\u003e\n\u003cli data-section-id=\"1ghqtvv\" data-start=\"4391\" data-end=\"4422\"\u003eHigh-capacity airflow design.\u003c\/li\u003e\n\u003cli data-section-id=\"1y2ocdl\" data-start=\"4423\" data-end=\"4453\"\u003eAirflow equalization system.\u003c\/li\u003e\n\u003cli data-section-id=\"hyq78z\" data-start=\"4454\" data-end=\"4483\"\u003eDual-stage dust collection.\u003c\/li\u003e\n\u003cli data-section-id=\"8hhpxg\" data-start=\"4484\" data-end=\"4525\"\u003eOptimized discharge airflow management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4527\" data-end=\"4741\"\u003eThe system provides up to \u003cstrong data-start=\"4553\" data-end=\"4599\"\u003e1,177 CFM (2,000 m³\/h) extraction capacity\u003c\/strong\u003e, delivering approximately \u003cstrong data-start=\"4626\" data-end=\"4650\"\u003e588 CFM (1,000 m³\/h)\u003c\/strong\u003e per arm when both arms are operating simultaneously.\u003c\/p\u003e\n\u003chr data-start=\"4743\" data-end=\"4746\"\u003e\n\u003ch2 data-section-id=\"1heyptf\" data-start=\"4748\" data-end=\"4792\"\u003eFlexible Filtration and Accessory Options\u003c\/h2\u003e\n\u003cp data-start=\"4794\" data-end=\"4874\"\u003eThe UNI 3.2.2 W3 can be configured to meet a variety of production requirements.\u003c\/p\u003e\n\u003cp data-start=\"4876\" data-end=\"4902\"\u003eAvailable options include:\u003c\/p\u003e\n\u003cul data-start=\"4904\" data-end=\"5099\"\u003e\n\u003cli data-section-id=\"1n5587v\" data-start=\"4904\" data-end=\"4954\"\u003eDual 6 in. (160 mm) articulated extraction arms.\u003c\/li\u003e\n\u003cli data-section-id=\"lrdh7h\" data-start=\"4955\" data-end=\"4988\"\u003eHood-mounted LED lighting kits.\u003c\/li\u003e\n\u003cli data-section-id=\"29xde1\" data-start=\"4989\" data-end=\"5025\"\u003eAdditional spark arrestor filters.\u003c\/li\u003e\n\u003cli data-section-id=\"1y08s8f\" data-start=\"5026\" data-end=\"5048\"\u003eH14 HEPA filtration.\u003c\/li\u003e\n\u003cli data-section-id=\"1k7o87x\" data-start=\"5049\" data-end=\"5099\"\u003eDischarge kit for external exhaust applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5101\" data-end=\"5239\"\u003eThese options allow facilities to tailor the system to specific welding and fabrication processes.\u003c\/p\u003e\n\u003chr data-start=\"5241\" data-end=\"5244\"\u003e\n\u003ch2 data-section-id=\"x43ryu\" data-start=\"5246\" data-end=\"5268\"\u003eSupported Processes\u003c\/h2\u003e\n\u003cp data-start=\"5270\" data-end=\"5303\"\u003eThe UNI 3.2.2 W3 is suitable for:\u003c\/p\u003e\n\u003cul data-start=\"5305\" data-end=\"5439\"\u003e\n\u003cli data-section-id=\"1l448pd\" data-start=\"5305\" data-end=\"5318\"\u003eMIG Welding\u003c\/li\u003e\n\u003cli data-section-id=\"1cggtnd\" data-start=\"5319\" data-end=\"5332\"\u003eMAG Welding\u003c\/li\u003e\n\u003cli data-section-id=\"116658u\" data-start=\"5333\" data-end=\"5357\"\u003ePulsed MIG\/MAG Welding\u003c\/li\u003e\n\u003cli data-section-id=\"qyiua0\" data-start=\"5358\" data-end=\"5371\"\u003eTIG Welding\u003c\/li\u003e\n\u003cli data-section-id=\"v9v5qy\" data-start=\"5372\" data-end=\"5393\"\u003eMMA \/ Stick Welding\u003c\/li\u003e\n\u003cli data-section-id=\"3717ra\" data-start=\"5394\" data-end=\"5417\"\u003eManual Plasma Cutting\u003c\/li\u003e\n\u003cli data-section-id=\"12uhkrc\" data-start=\"5418\" data-end=\"5439\"\u003eGrinding Operations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5441\" data-end=\"5562\"\u003eThe unit is designed for dry welding fumes and dust generated by these processes.\u003c\/p\u003e\n\u003chr data-start=\"5564\" data-end=\"5567\"\u003e\n\u003ch2 data-section-id=\"19vd27d\" data-start=\"5569\" data-end=\"5590\"\u003eIdeal Applications\u003c\/h2\u003e\n\u003cp data-start=\"5592\" data-end=\"5638\"\u003eThe UNI 3.2.2 W3 is an excellent solution for:\u003c\/p\u003e\n\u003cul data-start=\"5640\" data-end=\"5916\"\u003e\n\u003cli data-section-id=\"1pa6bpk\" data-start=\"5640\" data-end=\"5668\"\u003eDual welding workstations.\u003c\/li\u003e\n\u003cli data-section-id=\"1l5s5d2\" data-start=\"5669\" data-end=\"5705\"\u003eProduction fabrication facilities.\u003c\/li\u003e\n\u003cli data-section-id=\"a7lxog\" data-start=\"5706\" data-end=\"5733\"\u003eManufacturing operations.\u003c\/li\u003e\n\u003cli data-section-id=\"1igkd2o\" data-start=\"5734\" data-end=\"5765\"\u003eStructural steel fabrication.\u003c\/li\u003e\n\u003cli data-section-id=\"fjf2qc\" data-start=\"5766\" data-end=\"5795\"\u003eWelding and grinding cells.\u003c\/li\u003e\n\u003cli data-section-id=\"1jdu3hb\" data-start=\"5796\" data-end=\"5832\"\u003eIndustrial maintenance facilities.\u003c\/li\u003e\n\u003cli data-section-id=\"1y5hoys\" data-start=\"5833\" data-end=\"5875\"\u003eMulti-operator fabrication environments.\u003c\/li\u003e\n\u003cli data-section-id=\"3txqvz\" data-start=\"5876\" data-end=\"5916\"\u003eContinuous-duty production operations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5918\" data-end=\"5921\"\u003e\n\u003ch2 data-section-id=\"ms5cd3\" data-start=\"5923\" data-end=\"5954\"\u003eWho Is the UNI 3.2.2 W3 For?\u003c\/h2\u003e\n\u003cp data-start=\"5956\" data-end=\"6005\"\u003eThe UNI 3.2.2 W3 is ideal for organizations that:\u003c\/p\u003e\n\u003cul data-start=\"6007\" data-end=\"6342\"\u003e\n\u003cli data-section-id=\"nk8vlp\" data-start=\"6007\" data-end=\"6043\"\u003eOperate multiple welding stations.\u003c\/li\u003e\n\u003cli data-section-id=\"s1cze3\" data-start=\"6044\" data-end=\"6096\"\u003eRequire simultaneous extraction at two work areas.\u003c\/li\u003e\n\u003cli data-section-id=\"1uit1tg\" data-start=\"6097\" data-end=\"6130\"\u003eNeed automatic filter cleaning.\u003c\/li\u003e\n\u003cli data-section-id=\"sc1rdw\" data-start=\"6131\" data-end=\"6174\"\u003eWant W3-certified filtration performance.\u003c\/li\u003e\n\u003cli data-section-id=\"r42roa\" data-start=\"6175\" data-end=\"6219\"\u003eGenerate significant welding fume volumes.\u003c\/li\u003e\n\u003cli data-section-id=\"1dxq9so\" data-start=\"6220\" data-end=\"6269\"\u003ePerform grinding and plasma cutting operations.\u003c\/li\u003e\n\u003cli data-section-id=\"1yg9v8o\" data-start=\"6270\" data-end=\"6342\"\u003eNeed industrial-duty extraction with reduced maintenance requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6344\" data-end=\"6347\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"6349\" data-end=\"6364\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"6366\" data-end=\"6951\"\u003e\n\u003cli data-section-id=\"1jopxsz\" data-start=\"6366\" data-end=\"6420\"\u003eW3-certified filtration efficiency greater than 99%.\u003c\/li\u003e\n\u003cli data-section-id=\"wq2c4c\" data-start=\"6421\" data-end=\"6454\"\u003eDual-arm extraction capability.\u003c\/li\u003e\n\u003cli data-section-id=\"o37626\" data-start=\"6455\" data-end=\"6498\"\u003eAutomatic compressed-air filter cleaning.\u003c\/li\u003e\n\u003cli data-section-id=\"iz4sdv\" data-start=\"6499\" data-end=\"6534\"\u003eDual-cartridge filtration system.\u003c\/li\u003e\n\u003cli data-section-id=\"1d29ih\" data-start=\"6535\" data-end=\"6573\"\u003eSintexx Plus nanofiber filter media.\u003c\/li\u003e\n\u003cli data-section-id=\"p2jd1h\" data-start=\"6574\" data-end=\"6626\"\u003ePre-separation chamber for spark and dust removal.\u003c\/li\u003e\n\u003cli data-section-id=\"k8poj3\" data-start=\"6627\" data-end=\"6660\"\u003ePlug-fan extraction technology.\u003c\/li\u003e\n\u003cli data-section-id=\"q62kt\" data-start=\"6661\" data-end=\"6685\"\u003eDigital control panel.\u003c\/li\u003e\n\u003cli data-section-id=\"1g9zqyv\" data-start=\"6686\" data-end=\"6723\"\u003eAutomatic Start\/Stop functionality.\u003c\/li\u003e\n\u003cli data-section-id=\"ymte4a\" data-start=\"6724\" data-end=\"6752\"\u003eCompressed-air monitoring.\u003c\/li\u003e\n\u003cli data-section-id=\"1erkvn7\" data-start=\"6753\" data-end=\"6773\"\u003eAlarm history log.\u003c\/li\u003e\n\u003cli data-section-id=\"e5yl6c\" data-start=\"6774\" data-end=\"6797\"\u003eClogged filter alarm.\u003c\/li\u003e\n\u003cli data-section-id=\"1eszi9q\" data-start=\"6798\" data-end=\"6829\"\u003eDual dust collection drawers.\u003c\/li\u003e\n\u003cli data-section-id=\"1jy3ylp\" data-start=\"6830\" data-end=\"6868\"\u003eMobile industrial-duty construction.\u003c\/li\u003e\n\u003cli data-section-id=\"1aqzgg4\" data-start=\"6869\" data-end=\"6951\"\u003eCompatible with optional H14 filtration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6953\" data-end=\"6956\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"6958\" data-end=\"6985\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"6987\" data-end=\"7581\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"6987\" data-end=\"7019\"\u003e\n\u003ctr data-start=\"6987\" data-end=\"7019\"\u003e\n\u003cth data-start=\"6987\" data-end=\"7003\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"7003\" data-end=\"7019\" data-col-size=\"md\" class=\"last:pe-10\"\u003eUNI 3.2.2 W3\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"7052\" data-end=\"7581\"\u003e\n\u003ctr data-start=\"7052\" data-end=\"7093\"\u003e\n\u003ctd data-start=\"7052\" data-end=\"7067\" data-col-size=\"sm\"\u003eFan Capacity\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7067\" data-end=\"7093\"\u003e1,483 CFM (2,520 m³\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7094\" data-end=\"7142\"\u003e\n\u003ctd data-start=\"7094\" data-end=\"7116\" data-col-size=\"sm\"\u003eExtraction Capacity\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7116\" data-end=\"7142\"\u003e1,177 CFM (2,000 m³\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7143\" data-end=\"7197\"\u003e\n\u003ctd data-start=\"7143\" data-end=\"7173\" data-col-size=\"sm\"\u003eExtraction Capacity Per Arm\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7173\" data-end=\"7197\"\u003e588 CFM (1,000 m³\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7198\" data-end=\"7243\"\u003e\n\u003ctd data-start=\"7198\" data-end=\"7222\" data-col-size=\"sm\"\u003eFiltration Efficiency\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7222\" data-end=\"7243\"\u003eW3 Certified \u0026gt;99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7244\" data-end=\"7281\"\u003e\n\u003ctd data-start=\"7244\" data-end=\"7258\" data-col-size=\"sm\"\u003eFilter Area\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7258\" data-end=\"7281\"\u003e172 sq. ft. (16 m²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7282\" data-end=\"7323\"\u003e\n\u003ctd data-start=\"7282\" data-end=\"7297\" data-col-size=\"sm\"\u003eFilter Media\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7297\" data-end=\"7323\"\u003eSintexx Plus Nanofiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7324\" data-end=\"7355\"\u003e\n\u003ctd data-start=\"7324\" data-end=\"7338\" data-col-size=\"sm\"\u003eMotor Power\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7338\" data-end=\"7355\"\u003e2 HP (1.5 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7356\" data-end=\"7420\"\u003e\n\u003ctd data-start=\"7356\" data-end=\"7366\" data-col-size=\"sm\"\u003eVoltage\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7366\" data-end=\"7420\"\u003e230V \/ 1 Phase \/ 50Hz or 400V \/ 3 Phase \/ 50-60Hz*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7421\" data-end=\"7447\"\u003e\n\u003ctd data-start=\"7421\" data-end=\"7435\" data-col-size=\"sm\"\u003eNoise Level\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7435\" data-end=\"7447\"\u003e75 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7448\" data-end=\"7487\"\u003e\n\u003ctd data-start=\"7448\" data-end=\"7476\" data-col-size=\"sm\"\u003eCompressed Air Connection\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7476\" data-end=\"7487\"\u003e1\/2 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7488\" data-end=\"7550\"\u003e\n\u003ctd data-start=\"7488\" data-end=\"7501\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7501\" data-end=\"7550\"\u003e29.1 x 46.5 x 43.7 in. (740 x 1180 x 1110 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7551\" data-end=\"7581\"\u003e\n\u003ctd data-start=\"7551\" data-end=\"7560\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"7560\" data-end=\"7581\" data-col-size=\"md\"\u003e401 lbs. (182 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"7583\" data-end=\"7715\"\u003e*Verify final electrical configuration for North American installations before publication.\u003c\/p\u003e\n\u003chr data-start=\"7717\" data-end=\"7720\"\u003e\n\u003ch2 data-section-id=\"1xfdujf\" data-start=\"7722\" data-end=\"7759\"\u003eImportant Operating Considerations\u003c\/h2\u003e\n\u003cp data-start=\"7761\" data-end=\"7794\"\u003eThe UNI 3.2.2 W3 is designed for:\u003c\/p\u003e\n\u003cul data-start=\"7796\" data-end=\"7948\"\u003e\n\u003cli data-section-id=\"mola8r\" data-start=\"7796\" data-end=\"7816\"\u003eDry welding fumes.\u003c\/li\u003e\n\u003cli data-section-id=\"1o2i76u\" data-start=\"7817\" data-end=\"7833\"\u003eGrinding dust.\u003c\/li\u003e\n\u003cli data-section-id=\"lk6x8c\" data-start=\"7834\" data-end=\"7870\"\u003eManual plasma cutting particulate.\u003c\/li\u003e\n\u003cli data-section-id=\"1ycvy3h\" data-start=\"7871\" data-end=\"7911\"\u003eMulti-station production environments.\u003c\/li\u003e\n\u003cli data-section-id=\"xb3v95\" data-start=\"7912\" data-end=\"7948\"\u003eIntensive industrial applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"7950\" data-end=\"8197\"\u003eThe unit is \u003cstrong data-start=\"7962\" data-end=\"7993\"\u003enot suitable for oily fumes\u003c\/strong\u003e and is \u003cstrong data-start=\"8001\" data-end=\"8075\"\u003enot approved for use in potentially explosive or hazardous atmospheres\u003c\/strong\u003e. Operation of the automatic cleaning system requires a compressed-air connection.\u003c\/p\u003e\n\u003chr data-start=\"8199\" data-end=\"8202\"\u003e\n\u003ch2 data-section-id=\"1wmh05p\" data-start=\"8204\" data-end=\"8255\"\u003eBuilt for High-Productivity Welding Fume Control\u003c\/h2\u003e\n\u003cp data-start=\"8257\" data-end=\"8703\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe AerService UNI 3.2.2 W3 delivers industrial-grade welding fume extraction for facilities requiring simultaneous source capture at multiple welding stations. Combining dual-arm flexibility, automatic filter cleaning, W3-certified filtration, and advanced airflow management, the UNI 3.2.2 W3 provides a powerful solution for fabrication operations where productivity, coverage, and uptime are essential.\u003c\/p\u003e","brand":"AerService (Made in Italy)","offers":[{"title":"Default Title","offer_id":62805872509087,"sku":null,"price":6795.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0100\/8271\/3696\/files\/uni-322-w3-dual-arm-self-cleaning-mobile-filter-unit-for-welding-fumes-welding-fume-extraction-systems-quantum-machinery-group-usa-3484816.jpg?v=1780488066"}],"url":"https:\/\/quantummachinery.com\/collections\/welding-fume-extractors.oembed","provider":"QuantumMachinery","version":"1.0","type":"link"}